External electrical cardioversion in patients with cardiac implantable electronic devices: Is it safe and is immediate device interrogation necessary?. Issue 10 (28th August 2018)
- Record Type:
- Journal Article
- Title:
- External electrical cardioversion in patients with cardiac implantable electronic devices: Is it safe and is immediate device interrogation necessary?. Issue 10 (28th August 2018)
- Main Title:
- External electrical cardioversion in patients with cardiac implantable electronic devices: Is it safe and is immediate device interrogation necessary?
- Authors:
- Pluymaekers, Nikki AHA
Dudink, Elton AMP
Boersma, Lucas
Erküner, Ömer
Gelissen, Marloes
van Dijk, Vincent
Wijffels, Maurits
Dinh, Trang
Vernooy, Kevin
Crijns, Harry JGM
Balt, Jippe
Luermans, Justin GLM - Abstract:
- Abstract: Background: Atrial tachyarrhythmias are common in patients with cardiac implantable electronic devices (CIEDs). Restoration of sinus rhythm by external electrical cardioversion (eECV) is frequently used to alleviate symptoms and to ensure optimal device function. Objectives: To evaluate the safety of eECV in patients with contemporary CIEDs and to assess the need for immediate device interrogation after eECV. Methods: We conducted a retrospective observational study of 229 patients (27.9% female, age 69 ± 10 years) with a CIED (104 pacemakers, 69 implantable cardioverter defibrillators, and 56 biventricular devices) who underwent eECV between 2008 and 2016 in two centers. Data from device interrogation before eECV, immediately afterwards, and at first follow‐up (FU) after eECV were collected. CIED‐related complications and adverse events during and after eECV were recorded. Results: No significant differences between right atrial (RA) and right ventricular (RV) sensing or threshold values before eECV, immediately afterwards, or at FU were observed. A small yet significant decrease was observed in RA and RV impedance immediately after eECV (484 Ω vs 462 Ω, P < 0.001 and 536 Ω vs 514 Ω, P < 0.001, respectively). The RV impedance did not recover to the baseline value (538 Ω vs 527 Ω, P = 0.02). The impedance changes were without clinical consequences. No changes in left ventricular lead threshold or impedance values were measured. No CIED‐related complications orAbstract: Background: Atrial tachyarrhythmias are common in patients with cardiac implantable electronic devices (CIEDs). Restoration of sinus rhythm by external electrical cardioversion (eECV) is frequently used to alleviate symptoms and to ensure optimal device function. Objectives: To evaluate the safety of eECV in patients with contemporary CIEDs and to assess the need for immediate device interrogation after eECV. Methods: We conducted a retrospective observational study of 229 patients (27.9% female, age 69 ± 10 years) with a CIED (104 pacemakers, 69 implantable cardioverter defibrillators, and 56 biventricular devices) who underwent eECV between 2008 and 2016 in two centers. Data from device interrogation before eECV, immediately afterwards, and at first follow‐up (FU) after eECV were collected. CIED‐related complications and adverse events during and after eECV were recorded. Results: No significant differences between right atrial (RA) and right ventricular (RV) sensing or threshold values before eECV, immediately afterwards, or at FU were observed. A small yet significant decrease was observed in RA and RV impedance immediately after eECV (484 Ω vs 462 Ω, P < 0.001 and 536 Ω vs 514 Ω, P < 0.001, respectively). The RV impedance did not recover to the baseline value (538 Ω vs 527 Ω, P = 0.02). The impedance changes were without clinical consequences. No changes in left ventricular lead threshold or impedance values were measured. No CIED‐related complications or adverse events were documented following eECV. Conclusion: eECV in patients with contemporary CIEDs is safe. There seems to be no need for immediate device interrogation after eECV. … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 41:Issue 10(2018)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 41:Issue 10(2018)
- Issue Display:
- Volume 41, Issue 10 (2018)
- Year:
- 2018
- Volume:
- 41
- Issue:
- 10
- Issue Sort Value:
- 2018-0041-0010-0000
- Page Start:
- 1336
- Page End:
- 1340
- Publication Date:
- 2018-08-28
- Subjects:
- CIED -- external ECV -- immediate device interrogation -- safety
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.13467 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7614.xml