Adherence to quality criteria improves concordance between transient elastography and ElastPQ for liver stiffness assessment—A multicenter retrospective study. Issue 10 (October 2018)
- Record Type:
- Journal Article
- Title:
- Adherence to quality criteria improves concordance between transient elastography and ElastPQ for liver stiffness assessment—A multicenter retrospective study. Issue 10 (October 2018)
- Main Title:
- Adherence to quality criteria improves concordance between transient elastography and ElastPQ for liver stiffness assessment—A multicenter retrospective study
- Authors:
- Ferraioli, Giovanna
De Silvestri, Annalisa
Reiberger, Thomas
Taylor-Robinson, Simon D.
de Knegt, Robert J.
Maiocchi, Laura
Mare, Ruxandra
Bucsics, Theresa
Atzori, Sebastiana
Tinelli, Carmine
Sporea, Ioan - Abstract:
- Abstract: Background: Assessment of liver stiffness provides important diagnostic and prognostic information in patients with chronic liver disease. Aims: To investigate whether the use of quality criteria (i) improves the concordance between transient elastography (TE) and a novel point shear wave elastography technique (ElastPQ ® ) and (ii) impacts on the performance of ElastPQ ® for liver fibrosis staging using TE as the reference standard. Methods: In this multicenter retrospective study, data of patients undergoing liver stiffness measurements (LSM) in five European centers were collected. TE was performed with FibroScan ® (Echosens, France) and ElastPQ ® with EPIQ ® or Affiniti ® systems (Philips, The Netherlands). The agreement between TE and ElastPQ ® LSMs was assessed with Lin's concordance correlation coefficient (CCC). Diagnostic performance of ElastPQ ® was assessed by the area under receiver operating characteristic (AUROC) curves. Results: Overall, 664 patients were included: mean age: 54.8(13.5) years, main etiologies: viral hepatitis (83.1%) and NAFLD (7.5%). CCC increased significantly when LSMs with ElastPQ ® were obtained with IQR/M ≤ 30% (p < 0.001). The diagnostic performance of ElastPQ ® for fibrosis staging also increased if LSM values were obtained with IQR/M ≤ 30%. Conclusion: Quality criteria should be followed when using ElastPQ ® for LSM, since the concordance with TE fibrosis staging was better at an ElastPQ ® IQR/M ≤ 30.
- Is Part Of:
- Digestive and liver disease. Volume 50:Issue 10(2018)
- Journal:
- Digestive and liver disease
- Issue:
- Volume 50:Issue 10(2018)
- Issue Display:
- Volume 50, Issue 10 (2018)
- Year:
- 2018
- Volume:
- 50
- Issue:
- 10
- Issue Sort Value:
- 2018-0050-0010-0000
- Page Start:
- 1056
- Page End:
- 1061
- Publication Date:
- 2018-10
- Subjects:
- Diagnostic performance -- Liver fibrosis -- Multicenter studies -- Quality criteria -- Shear wave elastography
Digestive organs -- Diseases -- Periodicals
Liver -- Diseases -- Periodicals
616.33005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/15908658 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.dld.2018.03.033 ↗
- Languages:
- English
- ISSNs:
- 1590-8658
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3588.345600
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7599.xml