A hand-held device for rapid single tube detection of hepatitis-C virus. Issue 35 (8th August 2018)
- Record Type:
- Journal Article
- Title:
- A hand-held device for rapid single tube detection of hepatitis-C virus. Issue 35 (8th August 2018)
- Main Title:
- A hand-held device for rapid single tube detection of hepatitis-C virus
- Authors:
- Jogezai, Naqeebullah
Shabbir, Muhammad Imran - Abstract:
- Abstract : A Single Tube Analysis system using LAMP, LED and ION-sensing (STALLION) for pathogen derived RNA/DNA. Abstract : Hepatitis C virus (HCV) is a major threat to public health being the leading cause of chronic liver disease with 92 to 149 million people affected worldwide. A rapid and accurate diagnosis is a key to prevent viral transmission and the management of disease progression. Here we describe a hand-held device for rapid detection of HCV infection called as STALLION (Single Tube Analysis using LAMP, LED and ION-sensing). A custom detection probe was designed to dip into a PCR tube. The probe comprises an ion sensitive field effect transistor (ISFET), a micro-capillary based Ag/AgCl reference electrode and a temperature sensor. In vitro replication of HCV genomic RNA was performed by reverse transcription loop-mediated isothermal amplification (RT-LAMP) and detected in real-time by ISFET bio-sensing of released H + ions. Incubation at 60 °C was provided by a novel low-cost concept based on heat dissipated from power LED(s). With this system, HCV positive samples with 10 1, 10 2, 10 3 copies per ml were detected in as less as 30, 18 and 13 minutes respectively compared to no-template control (NTC). The detection limit was comparable to those of available methods such as nested PCR. No significant false positive signal was observed for HCV negative samples. The results can be viewed on an accompanying LCD screen or alternatively can be transferred to a computerAbstract : A Single Tube Analysis system using LAMP, LED and ION-sensing (STALLION) for pathogen derived RNA/DNA. Abstract : Hepatitis C virus (HCV) is a major threat to public health being the leading cause of chronic liver disease with 92 to 149 million people affected worldwide. A rapid and accurate diagnosis is a key to prevent viral transmission and the management of disease progression. Here we describe a hand-held device for rapid detection of HCV infection called as STALLION (Single Tube Analysis using LAMP, LED and ION-sensing). A custom detection probe was designed to dip into a PCR tube. The probe comprises an ion sensitive field effect transistor (ISFET), a micro-capillary based Ag/AgCl reference electrode and a temperature sensor. In vitro replication of HCV genomic RNA was performed by reverse transcription loop-mediated isothermal amplification (RT-LAMP) and detected in real-time by ISFET bio-sensing of released H + ions. Incubation at 60 °C was provided by a novel low-cost concept based on heat dissipated from power LED(s). With this system, HCV positive samples with 10 1, 10 2, 10 3 copies per ml were detected in as less as 30, 18 and 13 minutes respectively compared to no-template control (NTC). The detection limit was comparable to those of available methods such as nested PCR. No significant false positive signal was observed for HCV negative samples. The results can be viewed on an accompanying LCD screen or alternatively can be transferred to a computer or smart phone. The STALLION system provides analysis in a conventional PCR tube format avoiding any complex fluidics or instrumentation requirements. Such a system will be particularly useful for rapid and reliable clinical diagnosis of HCV RNA by users with no prior expertise and provide the basis for point-of-care (POC) testing in limited resource settings especially for developing countries. … (more)
- Is Part Of:
- Analytical methods. Volume 10:Issue 35(2018)
- Journal:
- Analytical methods
- Issue:
- Volume 10:Issue 35(2018)
- Issue Display:
- Volume 10, Issue 35 (2018)
- Year:
- 2018
- Volume:
- 10
- Issue:
- 35
- Issue Sort Value:
- 2018-0010-0035-0000
- Page Start:
- 4233
- Page End:
- 4241
- Publication Date:
- 2018-08-08
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c8ay00802g ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7593.xml