A meta-analysis of antibacterial envelope use in prevention of cardiovascular implantable electronic device infection. (May 2017)
- Record Type:
- Journal Article
- Title:
- A meta-analysis of antibacterial envelope use in prevention of cardiovascular implantable electronic device infection. (May 2017)
- Main Title:
- A meta-analysis of antibacterial envelope use in prevention of cardiovascular implantable electronic device infection
- Authors:
- Ali, Sajid
Kanjwal, Yousuf
Bruhl, Steven R.
Alo, Mohammed
Taleb, Mohammed
Ali, Syed S.
Kabour, Ameer
Khawaja, Owais - Abstract:
- Objectives: Cardiac implantable electronic device (CIED) infection has been a major clinical problem in addition to being a major financial burden. In spite of antimicrobial prophylaxis, CIED infection rates have been increasing disproportionately. We therefore conducted this meta-analysis to assess the role of TYRX antibiotic envelope for the prevention of CIED infection. Methods: Using extensive online search, we conducted a meta-analysis of studies reporting CIED infections with versus without the use of TYRX antibiotic envelope. A random-effect model was used, and between studies heterogeneity was estimated with I 2 . All analyses were performed with RevMan (version 5.0.20). Results: Five cohort studies were included in this meta-analysis. The pooled odds ratio (OR) of included studies was 0.29 [95% confidence interval (CI): 0.09–0.94; p < 0.004]. There was evidence of heterogeneity with I 2 of 58%. There was also evidence of publication bias on funnel plot analysis. On sensitivity analysis, no statistically significant difference was noted when stratified by study design or duration of follow-up. Conclusion: The results of our study demonstrate a significant beneficial effect of TYRX antibiotic envelope for the prevention of CIED infections.
- Is Part Of:
- Therapeutic advances in infectious disease. Volume 4:Number 3(2017:May)
- Journal:
- Therapeutic advances in infectious disease
- Issue:
- Volume 4:Number 3(2017:May)
- Issue Display:
- Volume 4, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 4
- Issue:
- 3
- Issue Sort Value:
- 2017-0004-0003-0000
- Page Start:
- 75
- Page End:
- 82
- Publication Date:
- 2017-05
- Subjects:
- cardiac implantable electronic device -- epidemiology -- infection -- TYRX envelope
Communicable diseases -- Treatment -- Periodicals
Infection -- Treatment -- Periodicals
616.905 - Journal URLs:
- http://tai.sagepub.com/ ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/2049936117702317 ↗
- Languages:
- English
- ISSNs:
- 2049-9361
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7579.xml