Design and development of a helium injection system to improve external leakage detection during liquid nitrogen immersion tests. (October 2016)
- Record Type:
- Journal Article
- Title:
- Design and development of a helium injection system to improve external leakage detection during liquid nitrogen immersion tests. (October 2016)
- Main Title:
- Design and development of a helium injection system to improve external leakage detection during liquid nitrogen immersion tests
- Authors:
- Townsend, Andrew
Mishra, Rakesh - Abstract:
- Highlights: An efficient helium injection system for cooling of liquid nitrogen is demonstrated. Investigation of liquid evaporation rate and gas saturation. Helium injection system sizing discussion. Abstract: The testing of assemblies for use in cryogenic systems commonly includes evaluation at or near operating (therefore cryogenic) temperature. Typical assemblies include valves and pumps for use in liquid oxygen-liquid hydrogen rocket engines. One frequently specified method of cryogenic external leakage testing requires the assembly, pressurized with gaseous helium (GHe), be immersed in a bath of liquid nitrogen (LN2 ) and allowed to thermally stabilize. Component interfaces are then visually inspected for leakage (bubbles). Unfortunately the liquid nitrogen will be boiling under normal, bench-top, test conditions. This boiling tends to mask even significant leakage. One little known and perhaps under-utilized property of helium is the seemingly counter-intuitive thermodynamic property that when ambient temperature helium is bubbled through boiling LN2 at a temperature of −195.8 °C, the temperature of the liquid nitrogen will reduce . This paper reports on the design and testing of a novel proof-of-concept helium injection control system confirming that it is possible to reduce the temperature of an LN2 bath below boiling point through the controlled injection of ambient temperature gaseous helium and then to efficiently maintain a reduced helium flow rate to maintain aHighlights: An efficient helium injection system for cooling of liquid nitrogen is demonstrated. Investigation of liquid evaporation rate and gas saturation. Helium injection system sizing discussion. Abstract: The testing of assemblies for use in cryogenic systems commonly includes evaluation at or near operating (therefore cryogenic) temperature. Typical assemblies include valves and pumps for use in liquid oxygen-liquid hydrogen rocket engines. One frequently specified method of cryogenic external leakage testing requires the assembly, pressurized with gaseous helium (GHe), be immersed in a bath of liquid nitrogen (LN2 ) and allowed to thermally stabilize. Component interfaces are then visually inspected for leakage (bubbles). Unfortunately the liquid nitrogen will be boiling under normal, bench-top, test conditions. This boiling tends to mask even significant leakage. One little known and perhaps under-utilized property of helium is the seemingly counter-intuitive thermodynamic property that when ambient temperature helium is bubbled through boiling LN2 at a temperature of −195.8 °C, the temperature of the liquid nitrogen will reduce . This paper reports on the design and testing of a novel proof-of-concept helium injection control system confirming that it is possible to reduce the temperature of an LN2 bath below boiling point through the controlled injection of ambient temperature gaseous helium and then to efficiently maintain a reduced helium flow rate to maintain a stabilized liquid temperature, enabling clear visual observation of components immersed within the LN2 . Helium saturation testing is performed and injection system sizing is discussed. … (more)
- Is Part Of:
- Cryogenics. Volume 79(2016)
- Journal:
- Cryogenics
- Issue:
- Volume 79(2016)
- Issue Display:
- Volume 79, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 79
- Issue:
- 2016
- Issue Sort Value:
- 2016-0079-2016-0000
- Page Start:
- 17
- Page End:
- 25
- Publication Date:
- 2016-10
- Subjects:
- Helium injection -- Nitrogen boiling suppression -- Cryogenic thermal control system -- Cryogenic external leakage testing
Low temperature engineering -- Periodicals
Low temperature research -- Periodicals
536.56 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00112275 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cryogenics.2016.07.002 ↗
- Languages:
- English
- ISSNs:
- 0011-2275
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3490.150000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7562.xml