Pyrosequencing analysis of bacterial diversity in dental unit waterlines. (15th September 2015)
- Record Type:
- Journal Article
- Title:
- Pyrosequencing analysis of bacterial diversity in dental unit waterlines. (15th September 2015)
- Main Title:
- Pyrosequencing analysis of bacterial diversity in dental unit waterlines
- Authors:
- Costa, Damien
Mercier, Anne
Gravouil, Kevin
Lesobre, Jérôme
Delafont, Vincent
Bousseau, Anne
Verdon, Julien
Imbert, Christine - Abstract:
- Abstract: Some infections cases due to exposure to output water from dental unit waterlines (DUWL) have been reported in the literature. However, this type of healthcare-associated risk has remained unclear and up until now the overall bacterial composition of DUWL has been poorly documented. In this study, 454 high-throughput pyrosequencing was used to investigate the bacterial community in seven dental offices (N = 7) and to identify potential bacterial pathogenic sequences. Dental unit waters (DUW) were collected from the tap water supplying units (Incoming Water; IW) to the output exposure point of the turbine handpiece (Output water; OW) following a stagnation period (OWS), and immediately after the last patient of the sampling day (OWA). A high bacterial diversity was revealed in DUW with 394 operational taxonomic units detected at the genus level. In addition to the inter-unit variability observed, results showed increased total bacterial cell concentration and shifts in bacterial community composition and abundance at the genus level, mainly within the Gamma - and Alpha-Proteobacteria class, as water circulated in the dental unit (DU). Results showed that 96.7%, 96.8% and 97.4% of the total sequences from IW, OWS and OWA respectively were common to the 3 defined water groups, thereby highlighting a common core microbiome. Results also suggested that stagnation and DU maintenance practices were critical to composition of the bacterial community. The presence ofAbstract: Some infections cases due to exposure to output water from dental unit waterlines (DUWL) have been reported in the literature. However, this type of healthcare-associated risk has remained unclear and up until now the overall bacterial composition of DUWL has been poorly documented. In this study, 454 high-throughput pyrosequencing was used to investigate the bacterial community in seven dental offices (N = 7) and to identify potential bacterial pathogenic sequences. Dental unit waters (DUW) were collected from the tap water supplying units (Incoming Water; IW) to the output exposure point of the turbine handpiece (Output water; OW) following a stagnation period (OWS), and immediately after the last patient of the sampling day (OWA). A high bacterial diversity was revealed in DUW with 394 operational taxonomic units detected at the genus level. In addition to the inter-unit variability observed, results showed increased total bacterial cell concentration and shifts in bacterial community composition and abundance at the genus level, mainly within the Gamma - and Alpha-Proteobacteria class, as water circulated in the dental unit (DU). Results showed that 96.7%, 96.8% and 97.4% of the total sequences from IW, OWS and OWA respectively were common to the 3 defined water groups, thereby highlighting a common core microbiome. Results also suggested that stagnation and DU maintenance practices were critical to composition of the bacterial community. The presence of potentially pathogenic genera was detected, including Pseudomonas and Legionella spp . Emerging and opportunistic pathogenic genera such as Mycobacterium, Propionibacterium and Stenotrophomonas were likewise recovered in DUW. For the first time, an exhaustive evaluation of the bacterial communities present in DUW was performed taking into account the circulation of water within the DU. This study highlights an ignored diversity of the DUWL bacterial community. Our findings also contribute to a better appreciation of the potential infectious risk associated with dental care and suggest the importance of better managing microbial quality in DUW. Graphical abstract: Highlights: 454 pyrosequencing provides an insight into bacterial community of DUW. Bacterial biomass and diversity were described according to the water circulation within the dental unit. Putative bacterial pathogens were prevalent in DUW. … (more)
- Is Part Of:
- Water research. Volume 81(2015)
- Journal:
- Water research
- Issue:
- Volume 81(2015)
- Issue Display:
- Volume 81, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 81
- Issue:
- 2015
- Issue Sort Value:
- 2015-0081-2015-0000
- Page Start:
- 223
- Page End:
- 231
- Publication Date:
- 2015-09-15
- Subjects:
- Dental unit waterlines (DUWL) -- Bacterial contamination -- Pyrosequencing -- Healthcare -- Pathogens
Water -- Pollution -- Research -- Periodicals
363.7394 - Journal URLs:
- http://catalog.hathitrust.org/api/volumes/oclc/1769499.html ↗
http://www.sciencedirect.com/science/journal/00431354 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.watres.2015.05.065 ↗
- Languages:
- English
- ISSNs:
- 0043-1354
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9273.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7554.xml