- Nowadays, biopsy is a decisive method of lung cancer diagnosis, whereas lung biopsy is time-consuming, complex and inaccurate. So a computed tomography–compatible robot for rapid and precise lung biopsy is developed in this article. According to the actual operation process, the robot is divided into two modules: 4-degree-of-freedom position module for location of puncture point is appropriate for patient's almost all positions and 3-degree-of-freedom tendon-based orientation module with remote center of motion is compact and computed tomography–compatible to orientate and insert needle automatically inside computed tomography bore. The workspace of the robot surrounds patient's thorax, and the needle tip forms a cone under patient's skin. A new error model of the robot based on screw theory is proposed in view of structure error and actuation error, which are regarded as screw motions. Simulation is carried out to verify the precision of the error model contrasted with compensation via inverse kinematics. The results of insertion experiment on specific phantom prove the feasibility of the robot with mean error of 1.373 mm in laboratory environment, which is accurate enough to replace manual operation.
- Is Part Of:
- Proceedings of the Institution of Mechanical Engineers. Volume 231:Number 4(2017:Apr.)
- Journal:
- Proceedings of the Institution of Mechanical Engineers
- Issue:
- Volume 231:Number 4(2017:Apr.)
- Issue Display:
- Volume 231, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 231
- Issue:
- 4
- Issue Sort Value:
- 2017-0231-0004-0000
- Page Start:
- 286
- Page End:
- 298
- Publication Date:
- 2017-04
- Subjects:
- Lung biopsy -- computed tomography–compatible robot -- remote center of motion -- tendon–sheath -- kinematics analysis -- error analysis
Biomedical engineering -- Periodicals
Medical instruments and apparatus -- Periodicals
610.28 - Journal URLs:
- http://pih.sagepub.com/ ↗
http://journals.pepublishing.com/content/119779 ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0954411917690763 ↗
- Languages:
- English
- ISSNs:
- 0954-4119
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7554.xml