Can Vco2-Based Estimates of Resting Energy Expenditure Replace the Need for Indirect Calorimetry in Critically Ill Children?. (May 2017)
- Record Type:
- Journal Article
- Title:
- Can Vco2-Based Estimates of Resting Energy Expenditure Replace the Need for Indirect Calorimetry in Critically Ill Children?. (May 2017)
- Main Title:
- Can Vco2-Based Estimates of Resting Energy Expenditure Replace the Need for Indirect Calorimetry in Critically Ill Children?
- Authors:
- Mouzaki, Marialena
Schwartz, Steven M.
Mtaweh, Haifa
La Rotta, Gustavo
Mah, Kandice
Herridge, Joann
Van Arsdell, Glen
Parshuram, Christopher S.
Floh, Alejandro A. - Abstract:
- Background: Optimal energy provision, guided by measured resting energy expenditure (REE), is fundamental in the care of critically ill children. REE should be determined by indirect calorimetry (IC), which has limited availability. Recently, a novel equation was developed for estimating REE derived from carbon dioxide production (Vco 2 ). The aim of this study was to validate the accuracy of this equation in a population of critically ill children following cardiopulmonary bypass (CPB). Methods: This is an ancillary study to a larger trial of children undergoing CPB. Respiratory mass spectrometry was used measure oxygen consumption (Vo 2 ) and Vco 2 . REE was then calculated according to the established Weir equation (REEW ) and the modified, Vco 2 -based equation (REECO2 ). The agreement between the 2 measurements was assessed using Bland-Altman plots and mixed-model regressions accounting for repeated measures. Results: Data from 104 patients, which included 575 paired measurements, were included. The agreement between REEW and REECO2 was biased during the 72-hour observation period post CPB, with a mean percentage error between measurements of 11% (±7%). The most important determinant of the bias with the Vco 2 -based equation was the respiratory quotient (RQ). The percentage error between REEW and REECO2 dropped to 4.4% (±2.4%) in those with an RQ between 0.8 and 1. The within-subject variability for RQ in this cohort was wide (11%). Conclusions: IC remains the mostBackground: Optimal energy provision, guided by measured resting energy expenditure (REE), is fundamental in the care of critically ill children. REE should be determined by indirect calorimetry (IC), which has limited availability. Recently, a novel equation was developed for estimating REE derived from carbon dioxide production (Vco 2 ). The aim of this study was to validate the accuracy of this equation in a population of critically ill children following cardiopulmonary bypass (CPB). Methods: This is an ancillary study to a larger trial of children undergoing CPB. Respiratory mass spectrometry was used measure oxygen consumption (Vo 2 ) and Vco 2 . REE was then calculated according to the established Weir equation (REEW ) and the modified, Vco 2 -based equation (REECO2 ). The agreement between the 2 measurements was assessed using Bland-Altman plots and mixed-model regressions accounting for repeated measures. Results: Data from 104 patients, which included 575 paired measurements, were included. The agreement between REEW and REECO2 was biased during the 72-hour observation period post CPB, with a mean percentage error between measurements of 11% (±7%). The most important determinant of the bias with the Vco 2 -based equation was the respiratory quotient (RQ). The percentage error between REEW and REECO2 dropped to 4.4% (±2.4%) in those with an RQ between 0.8 and 1. The within-subject variability for RQ in this cohort was wide (11%). Conclusions: IC remains the most accurate method to determine the REE of critically ill patients. Widespread availability of Vco 2 data renders Vco 2 -based approaches to measurement of REE attractive; however, further research is needed to ensure that REE is estimated accurately. … (more)
- Is Part Of:
- JPEN, Journal of parenteral and enteral nutrition. Volume 41:Number 4(2017)
- Journal:
- JPEN, Journal of parenteral and enteral nutrition
- Issue:
- Volume 41:Number 4(2017)
- Issue Display:
- Volume 41, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 41
- Issue:
- 4
- Issue Sort Value:
- 2017-0041-0004-0000
- Page Start:
- 619
- Page End:
- 624
- Publication Date:
- 2017-05
- Subjects:
- energy expenditure -- indirect calorimetry -- critical care -- pediatrics
Parenteral feeding -- Periodicals
Enteral feeding -- Periodicals
615.85484 - Journal URLs:
- http://pen.sagepub.com/ ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/0148607115627143 ↗
- Languages:
- English
- ISSNs:
- 0148-6071
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5029.100000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7573.xml