An Analysis of Reliability and Accuracy of Muscle Thickness Ultrasonography in Critically Ill Children and Adults. (September 2016)
- Record Type:
- Journal Article
- Title:
- An Analysis of Reliability and Accuracy of Muscle Thickness Ultrasonography in Critically Ill Children and Adults. (September 2016)
- Main Title:
- An Analysis of Reliability and Accuracy of Muscle Thickness Ultrasonography in Critically Ill Children and Adults
- Authors:
- Fivez, Tom
Hendrickx, Alexandra
Van Herpe, Tom
Vlasselaers, Dirk
Desmet, Lars
Van den Berghe, Greet
Mesotten, Dieter - Abstract:
- Background: Muscle wasting starts already within the first week in critically patients and is strongly related to poor outcome. Nevertheless, the early detection of muscle wasting is difficult. Therefore, we investigated the reliability and accuracy of ultrasonography to evaluate skeletal muscle wasting in critically ill children and adults. Methods : This prospective observational study enrolled 30 sedated critically ill children and 14 critically ill adults. Two independent investigators made 210 ultrasonographical assessments of muscle thigh thickness. Inter- and intraobserver reliability and cutoff levels were calculated as a function of muscle thickness and the expected reduction in muscle size (predefined at 20% and 30%). Results : Mean ± SD muscle thickness was 1.67 ± 0.55 cm in the pediatric and 2.10 ± 0.85 cm in the adult population. The median absolute interobserver variability was 0.07 cm (interquartile range [IQR], 0.04–0.20 cm) in the pediatric population and 0.05 cm (IQR, 0.03–0.09 cm) in the adult population. However, the absolute intraobserver accuracy had a 95% confidence interval of 0.43 cm in children and 0.22 cm in adults. Only a 30% decrease (0.50 cm) in muscle thickness can be detected in critically ill children. Conclusion : Although the interobserver variability is acceptable in the pediatric population, the intraobserver variability is too large with respect to the expected reduction in muscle thickness. In adults, ultrasonography may be a reliableBackground: Muscle wasting starts already within the first week in critically patients and is strongly related to poor outcome. Nevertheless, the early detection of muscle wasting is difficult. Therefore, we investigated the reliability and accuracy of ultrasonography to evaluate skeletal muscle wasting in critically ill children and adults. Methods : This prospective observational study enrolled 30 sedated critically ill children and 14 critically ill adults. Two independent investigators made 210 ultrasonographical assessments of muscle thigh thickness. Inter- and intraobserver reliability and cutoff levels were calculated as a function of muscle thickness and the expected reduction in muscle size (predefined at 20% and 30%). Results : Mean ± SD muscle thickness was 1.67 ± 0.55 cm in the pediatric and 2.10 ± 0.85 cm in the adult population. The median absolute interobserver variability was 0.07 cm (interquartile range [IQR], 0.04–0.20 cm) in the pediatric population and 0.05 cm (IQR, 0.03–0.09 cm) in the adult population. However, the absolute intraobserver accuracy had a 95% confidence interval of 0.43 cm in children and 0.22 cm in adults. Only a 30% decrease (0.50 cm) in muscle thickness can be detected in critically ill children. Conclusion : Although the interobserver variability is acceptable in the pediatric population, the intraobserver variability is too large with respect to the expected reduction in muscle thickness. In adults, ultrasonography may be a reliable tool for early detection of muscle mass wasting. … (more)
- Is Part Of:
- JPEN, Journal of parenteral and enteral nutrition. Volume 40:Number 7(2016)
- Journal:
- JPEN, Journal of parenteral and enteral nutrition
- Issue:
- Volume 40:Number 7(2016)
- Issue Display:
- Volume 40, Issue 7 (2016)
- Year:
- 2016
- Volume:
- 40
- Issue:
- 7
- Issue Sort Value:
- 2016-0040-0007-0000
- Page Start:
- 944
- Page End:
- 949
- Publication Date:
- 2016-09
- Subjects:
- ultrasonography -- wasting syndrome -- critical illness -- child -- skeletal muscle
Parenteral feeding -- Periodicals
Enteral feeding -- Periodicals
615.85484 - Journal URLs:
- http://pen.sagepub.com/ ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/0148607115575033 ↗
- Languages:
- English
- ISSNs:
- 0148-6071
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5029.100000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7555.xml