Evaluation of radiographic fracture position 1 year after variable angle locking volar distal radius plating: a prospective multicentre case series. (June 2017)
- Record Type:
- Journal Article
- Title:
- Evaluation of radiographic fracture position 1 year after variable angle locking volar distal radius plating: a prospective multicentre case series. (June 2017)
- Main Title:
- Evaluation of radiographic fracture position 1 year after variable angle locking volar distal radius plating: a prospective multicentre case series
- Authors:
- Teunis, T.
Jupiter, J.
Schaser, K. D.
Fronhöfer, G.
Babst, R.
Langer, M.
Platz, A.
Schierz, A.
Joeris, A.
Rikli, D. - Abstract:
- Treatment with a variable angle locking plate can, in theory, maintain near anatomic reduction of intra-articular distal radius fractures, but it is unknown to what extent reduction is maintained as measured by computed tomography. We assessed changes in radiographic fracture position 1 year post-operatively. We included 73 patients of whom 66 patients (90%) had radiographs available for review at 1 year post-operatively. We found a small (less than 2 mm or 2°) but statistically significant change in several measures. Accounting for inter-observer variability, this is probably within measurement error. We found no difference in change in fracture position or range of motion, grip strength or patient-reported outcome between the use of one or two distal rows of screws. Our results show that minimal changes in reduction can be expected after volar plate fixation in most patients. We recommend using only one screw row routinely, limiting costs, surgical time and the risk of misplacement of screws. Level of evidence: IV
- Is Part Of:
- Journal of hand surgery. Volume 42:Number 5(2017:Jun.)
- Journal:
- Journal of hand surgery
- Issue:
- Volume 42:Number 5(2017:Jun.)
- Issue Display:
- Volume 42, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 42
- Issue:
- 5
- Issue Sort Value:
- 2017-0042-0005-0000
- Page Start:
- 493
- Page End:
- 500
- Publication Date:
- 2017-06
- Subjects:
- Distal radius -- fractures -- volar locking plate -- alignment
617.575059 - Journal URLs:
- http://jhs.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1753193417690478 ↗
- Languages:
- English
- ISSNs:
- 1753-1934
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4996.623300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7534.xml