Electrochemical determination of lead in human blood serum and urine by anodic stripping voltammetry using glassy carbon electrodes covered with Ag–Hg and Ag–Bi bimetallic nanoparticles. Issue 34 (20th July 2018)
- Record Type:
- Journal Article
- Title:
- Electrochemical determination of lead in human blood serum and urine by anodic stripping voltammetry using glassy carbon electrodes covered with Ag–Hg and Ag–Bi bimetallic nanoparticles. Issue 34 (20th July 2018)
- Main Title:
- Electrochemical determination of lead in human blood serum and urine by anodic stripping voltammetry using glassy carbon electrodes covered with Ag–Hg and Ag–Bi bimetallic nanoparticles
- Authors:
- Valera, Danny
Sánchez, Mireya
Domínguez, José R.
Alvarado, José
Espinoza-Montero, Patricio J.
Carrera, Patricio
Bonilla, Pablo
Manciati, Carla
González, Gema
Fernández, Lenys - Abstract:
- Abstract : The evaluation and application of glassy carbon electrodes modified with bimetallic nanoparticle deposits. Abstract : The evaluation and application of glassy carbon electrodes modified with bimetallic nanoparticle deposits of Ag–Hg and Ag–Bi for determination of Pb(ii ) is described. Deposition of the nanostructured bimetallic combinations on top of the glassy carbon (GC) substrate, previously covered with a Nafion (Nf) film, resulted in electrodes with substantially enlarged hydrogen evolution over-voltage. As indicated by scanning electron microscopy and atomic force microscopy images, most of the deposited nanoparticles, with an average size of 150 nm, were uniformly dispersed inside the Nafion net while a smaller amount remained on top of the embedded ones. Sensitivity tests of the AgBiNpNf/GC modified electrode produced a detection limit (DL), based on the 3s criterion, of 0.66 μg L −1 and 0.24 μg L −1 for the AgHgNpNf/GC electrode. Accuracy was assessed by comparison with quantification of Pb(ii ) in human blood serum and urine samples analyzed by atomic absorption spectrometry, using a continuous source high resolution atomic absorption spectrometer.
- Is Part Of:
- Analytical methods. Volume 10:Issue 34(2018)
- Journal:
- Analytical methods
- Issue:
- Volume 10:Issue 34(2018)
- Issue Display:
- Volume 10, Issue 34 (2018)
- Year:
- 2018
- Volume:
- 10
- Issue:
- 34
- Issue Sort Value:
- 2018-0010-0034-0000
- Page Start:
- 4114
- Page End:
- 4121
- Publication Date:
- 2018-07-20
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c8ay01314d ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7538.xml