Fatigue behavior and crack initiation of CAD/CAM resin composite molar crowns. Issue 10 (October 2018)
- Record Type:
- Journal Article
- Title:
- Fatigue behavior and crack initiation of CAD/CAM resin composite molar crowns. Issue 10 (October 2018)
- Main Title:
- Fatigue behavior and crack initiation of CAD/CAM resin composite molar crowns
- Authors:
- Yamaguchi, Satoshi
Kani, Renshirou
Kawakami, Kazuma
Tsuji, Manami
Inoue, Sayuri
Lee, Chunwoo
Kiba, Wakako
Imazato, Satoshi - Abstract:
- Highlights: Fatigue behaviour of CAD/CAM resin composite molar crowns was assessed. Crack initiation of CAD/CAM resin composite molar crowns was analysed. Fracture loads of CS and KA were significantly greater than that of HC. Fracture probabilities at 120, 000 cycles of KA were the lowest. CAD/CAM resin composite crowns could be used as an alternative to ceramics. Abstract: Objective: The aim of this study was to evaluate long-term fatigue behavior using an in vitro step-stress accelerated life test (SSALT), and to determine the crack initiation point using in silico finite element analysis for computer-aided designed and manufactured (CAD/CAM) molar crowns fabricated from three commercial CAD/CAM resin composite blocks: Cerasmart (CS; GC, Tokyo, Japan), Katana Avencia Block (KA; Kuraray Noritake Dental, Niigata, Japan), and Shofu Block HC (HC; Shofu, Kyoto, Japan). Methods: Fifty-one mandibular first molar crowns luted on a resin core die were embedded in acrylic resin and covered with a polyvinyl chloride tube. Single compressive tests were performed for five crowns. SSALT was conducted for 36 crowns using three profiles and reliabilities at 120, 000 cycles, and a Weibull analysis was conducted. The maximum principal strain of each CAD/CAM resin composite crown model was analyzed by three-dimensional finite element analysis. Results: Fracture loads of CS and KA (3784 ± 144 N and 3915 ± 313 N) were significantly greater than that of HC (2767 ± 227 N) ( p < 0.05). FractureHighlights: Fatigue behaviour of CAD/CAM resin composite molar crowns was assessed. Crack initiation of CAD/CAM resin composite molar crowns was analysed. Fracture loads of CS and KA were significantly greater than that of HC. Fracture probabilities at 120, 000 cycles of KA were the lowest. CAD/CAM resin composite crowns could be used as an alternative to ceramics. Abstract: Objective: The aim of this study was to evaluate long-term fatigue behavior using an in vitro step-stress accelerated life test (SSALT), and to determine the crack initiation point using in silico finite element analysis for computer-aided designed and manufactured (CAD/CAM) molar crowns fabricated from three commercial CAD/CAM resin composite blocks: Cerasmart (CS; GC, Tokyo, Japan), Katana Avencia Block (KA; Kuraray Noritake Dental, Niigata, Japan), and Shofu Block HC (HC; Shofu, Kyoto, Japan). Methods: Fifty-one mandibular first molar crowns luted on a resin core die were embedded in acrylic resin and covered with a polyvinyl chloride tube. Single compressive tests were performed for five crowns. SSALT was conducted for 36 crowns using three profiles and reliabilities at 120, 000 cycles, and a Weibull analysis was conducted. The maximum principal strain of each CAD/CAM resin composite crown model was analyzed by three-dimensional finite element analysis. Results: Fracture loads of CS and KA (3784 ± 144 N and 3915 ± 313 N) were significantly greater than that of HC (2767 ± 227 N) ( p < 0.05). Fracture probabilities at 120, 000 cycles were 24.6% (CS), 13.7% (KA), and 14.0% (HC). Maximum principal strain was observed around the mesiolingual cusps of CS and KA and the distobuccal cusp of HC. Significance: CAD/CAM resin composite molar crowns containing nano-fillers with a higher fraction of resin matrix exhibited higher fracture loads and greater longevity, suggesting that these crowns could be used as an alternative to ceramic crowns in terms of fatigue behavior. … (more)
- Is Part Of:
- Dental materials. Volume 34:Issue 10(2018)
- Journal:
- Dental materials
- Issue:
- Volume 34:Issue 10(2018)
- Issue Display:
- Volume 34, Issue 10 (2018)
- Year:
- 2018
- Volume:
- 34
- Issue:
- 10
- Issue Sort Value:
- 2018-0034-0010-0000
- Page Start:
- 1578
- Page End:
- 1584
- Publication Date:
- 2018-10
- Subjects:
- CAD/CAM computer-aided design/computer-aided manufacturing -- SSALT step-stress accelerated life test -- FEA finite element analysis -- MPS maximum principal strain -- RCB resin composite block -- PVC polyvinyl chloride -- XRD X-ray diffraction -- SEM scanning electron microscopy -- ANOVA analysis of variance -- HSD honest significant difference
CAD/CAM resin composite molar crown -- CAD/CAM resin composite -- Fatigue resistance -- Step-stress accelerated life testing -- Three-dimensional finite element analysis
Dentistry -- Periodicals
Dental materials -- Periodicals
617.695 - Journal URLs:
- http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science/journal/01095641/ ↗ - DOI:
- 10.1016/j.dental.2018.07.002 ↗
- Languages:
- English
- ISSNs:
- 0109-5641
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3553.365800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7529.xml