Predictors for unsuccessful pessary fitting in women with symptomatic pelvic organ prolapse: a prospective study. (29th May 2018)
- Record Type:
- Journal Article
- Title:
- Predictors for unsuccessful pessary fitting in women with symptomatic pelvic organ prolapse: a prospective study. (29th May 2018)
- Main Title:
- Predictors for unsuccessful pessary fitting in women with symptomatic pelvic organ prolapse: a prospective study
- Authors:
- Mao, M
Ai, F
Zhang, Y
Kang, J
Liang, S
Xu, T
Zhu, L - Abstract:
- Abstract : Objective: To evaluate the success rate of vaginal pessary fitting and identify the risk factors associated with unsuccessful pessary fitting in a large cohort of patients with symptomatic pelvic organ prolapse (POP). Design: Prospective observational study. Setting: The Department of Obstetrics and Gynaecology, Peking Union Medical College Hospital, Beijing, China. Population: Women with symptomatic POP between May 2015 and December 2016 ( n = 343). Methods: A successful pessary fitting was defined as a patient fitted with a pessary at the initial fitting and continued use 2 weeks later. The independent samples t ‐test, non‐parametric test, Chi‐square test, Fisher's exact test, logistic regression and receiver operating characteristic curves were used for the data analysis. Main outcome measures: The success rate of vaginal pessary fitting and the risk factors associated with unsuccessful pessary fitting. Results: 302 patients had successful pessary fitting (88.0% success rate). A higher body mass index [BMI; 24.7 ± 3.1 kg/m 2 in the successful group versus 25.7 ± 3.8 kg/m 2 in the unsuccessful group, odds ratio (OR) 1.174, 95% CI 1.055–1.307, P = 0.003] and a shorter TVL [8.0 (8–9) cm in the successful group versus 7.0 (6.8–8) cm in the unsuccessful group, OR 0.338, 95% CI 0.223–0.513, P < 0.001) were independent predictors of an unsuccessful pessary fitting. The receiver operating characteristic curve showed that patients with a total vaginal lengthAbstract : Objective: To evaluate the success rate of vaginal pessary fitting and identify the risk factors associated with unsuccessful pessary fitting in a large cohort of patients with symptomatic pelvic organ prolapse (POP). Design: Prospective observational study. Setting: The Department of Obstetrics and Gynaecology, Peking Union Medical College Hospital, Beijing, China. Population: Women with symptomatic POP between May 2015 and December 2016 ( n = 343). Methods: A successful pessary fitting was defined as a patient fitted with a pessary at the initial fitting and continued use 2 weeks later. The independent samples t ‐test, non‐parametric test, Chi‐square test, Fisher's exact test, logistic regression and receiver operating characteristic curves were used for the data analysis. Main outcome measures: The success rate of vaginal pessary fitting and the risk factors associated with unsuccessful pessary fitting. Results: 302 patients had successful pessary fitting (88.0% success rate). A higher body mass index [BMI; 24.7 ± 3.1 kg/m 2 in the successful group versus 25.7 ± 3.8 kg/m 2 in the unsuccessful group, odds ratio (OR) 1.174, 95% CI 1.055–1.307, P = 0.003] and a shorter TVL [8.0 (8–9) cm in the successful group versus 7.0 (6.8–8) cm in the unsuccessful group, OR 0.338, 95% CI 0.223–0.513, P < 0.001) were independent predictors of an unsuccessful pessary fitting. The receiver operating characteristic curve showed that patients with a total vaginal length (TVL) less than 7.3 cm had a higher unsuccessful pessary fitting rate (sensitivity = 0.82, specificity = 0.64). Conclusions: A higher BMI and shorter TVL were independent predictors of an unsuccessful pessary fitting. Patients with a TVL <7.3 cm are not appropriate candidates for a vaginal pessary. Tweetable abstract: A higher BMI and shorter TVL (<7.3 cm) were independent predictors of an unsuccessful pessary fitting. Tweetable abstract: A higher BMI and shorter TVL (<7.3 cm) were independent predictors of an unsuccessful pessary fitting. … (more)
- Is Part Of:
- BJOG. Volume 125:Number 11(2018)
- Journal:
- BJOG
- Issue:
- Volume 125:Number 11(2018)
- Issue Display:
- Volume 125, Issue 11 (2018)
- Year:
- 2018
- Volume:
- 125
- Issue:
- 11
- Issue Sort Value:
- 2018-0125-0011-0000
- Page Start:
- 1434
- Page End:
- 1440
- Publication Date:
- 2018-05-29
- Subjects:
- Predictor -- symptomatic pelvic organ prolapse -- unsuccessful pessary fitting
Obstetrics -- Periodicals
Gynecology -- Periodicals
618 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1470-0328&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/1471-0528.15260 ↗
- Languages:
- English
- ISSNs:
- 1470-0328
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2105.748000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7532.xml