Use of Bivector Traction for Stabilization of the Head and Maintenance of Optimal Cervical Alignment in Posterior Cervical Fusions. (May 2017)
- Record Type:
- Journal Article
- Title:
- Use of Bivector Traction for Stabilization of the Head and Maintenance of Optimal Cervical Alignment in Posterior Cervical Fusions. (May 2017)
- Main Title:
- Use of Bivector Traction for Stabilization of the Head and Maintenance of Optimal Cervical Alignment in Posterior Cervical Fusions
- Authors:
- Karikari, Isaac O.
Bumpass, David B.
Gum, Jeffrey
Sugrue, Patrick
Chapman, Todd M.
Elsamadicy, Aladine A.
Riew, K. Daniel - Abstract:
- Study Design: Retrospective analysis of consecutive case series. Objective: To introduce a novel method of stabilizing the cranium using bivector traction in posterior cervical fusions. Methods: A retrospective review of 50 consecutive patients undergoing instrumented posterior cervical arthrodesis was performed. All patients had at least 3 levels of subaxial fusion using the bivector traction apparatus. Patients' demographic data was recorded for the following: pre- and postoperative cervical lordosis, pre- and postoperative cervical sagittal vertical alignment (cSVA), and intraoperative complications from pin placements. Results: A total of 50 patients were studied. There were 31 females and 19 males. The mean age at the time of surgery was 49 years (range 35-79). A mean 5.8 levels were fused. The most common levels fused were C2-T3 in 14 patients followed by C2-T2 in 7 patients. In no case did the surgeon or assistant have to scrub out to adjust the alignment. The mean pre- and postoperative cervical lordosis was −6.0° and −10°, respectively ( P = .04). The mean pre-and postoperative cSVA was 30.5 mm and 32 mm, respectively ( P = .6). There were no complications related to placement of the Gardner-Well tongs. Conclusion: The bivector traction is an easy, safe, and effective method of stabilizing the head and obtaining adequate cervical sagittal alignment.
- Is Part Of:
- Global spine journal. Volume 7:Number 3(2017)
- Journal:
- Global spine journal
- Issue:
- Volume 7:Number 3(2017)
- Issue Display:
- Volume 7, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 7
- Issue:
- 3
- Issue Sort Value:
- 2017-0007-0003-0000
- Page Start:
- 227
- Page End:
- 229
- Publication Date:
- 2017-05
- Subjects:
- cervical fusions -- posterior -- Mayfield headholder -- cranium -- Gardner-Wells tongs -- traction -- bivector -- cervical alignment
Spine -- Diseases -- Periodicals
Spine -- Diseases -- Treatment -- Periodicals
Spine -- Abnormalities -- Periodicals
Spine -- Surgery -- Periodicals
616.73 - Journal URLs:
- http://www.thieme.com/ ↗
- DOI:
- 10.1177/2192568217694146 ↗
- Languages:
- English
- ISSNs:
- 2192-5682
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7518.xml