Effect of ceiling extraction system on the smoke thermal stratification in the longitudinal ventilation tunnel. (25th October 2016)
- Record Type:
- Journal Article
- Title:
- Effect of ceiling extraction system on the smoke thermal stratification in the longitudinal ventilation tunnel. (25th October 2016)
- Main Title:
- Effect of ceiling extraction system on the smoke thermal stratification in the longitudinal ventilation tunnel
- Authors:
- Li, L.J.
Tang, F.
Dong, M.S.
Tao, C.F. - Abstract:
- Highlights: Smoke thermal stratification was investigated in a 72 m long model tunnel. The coupling effect of ceiling extraction and longitudinal ventilation considered. A modified Fr was proposed to describe the influence of ceiling extraction. Proposed correlation was to be applicable with and without ceiling extraction. Abstract: Poisonous and harmful smoke is one of the most important factors in the life-threatening in tunnel fires. In the event of fire, the effective control of fire growth and smoke sinking is crucial for personnel security in tunnel. The aim of this work is to study the smoke thermal stratification with ceiling extraction in a longitudinal ventilated tunnel. A series of experiments were carried out in a 1/6 scale model tunnel [72 m (length) × 1.5 m (width) × 1.3 m (height)]. Four thermocouple trees are used to measure vertical temperature profile. The heat release rate, ceiling extraction velocity and longitudinal forced air flow velocity were considered. It was found that: (a) the smoke temperature below the tunnel ceiling decreased and the thermal stratification stability reduced with the increasing of ceiling extraction velocity; (b) the measured temperatures ratios ΔTcf /ΔTh versus ΔTcf /ΔTavg with and without ceiling extraction are in good agreement with Nyman and Ingason's work; (c) with the coupling effect of ceiling extraction and longitudinal forced air flow, a modified Froude number was proposed to describe the influence of ceilingHighlights: Smoke thermal stratification was investigated in a 72 m long model tunnel. The coupling effect of ceiling extraction and longitudinal ventilation considered. A modified Fr was proposed to describe the influence of ceiling extraction. Proposed correlation was to be applicable with and without ceiling extraction. Abstract: Poisonous and harmful smoke is one of the most important factors in the life-threatening in tunnel fires. In the event of fire, the effective control of fire growth and smoke sinking is crucial for personnel security in tunnel. The aim of this work is to study the smoke thermal stratification with ceiling extraction in a longitudinal ventilated tunnel. A series of experiments were carried out in a 1/6 scale model tunnel [72 m (length) × 1.5 m (width) × 1.3 m (height)]. Four thermocouple trees are used to measure vertical temperature profile. The heat release rate, ceiling extraction velocity and longitudinal forced air flow velocity were considered. It was found that: (a) the smoke temperature below the tunnel ceiling decreased and the thermal stratification stability reduced with the increasing of ceiling extraction velocity; (b) the measured temperatures ratios ΔTcf /ΔTh versus ΔTcf /ΔTavg with and without ceiling extraction are in good agreement with Nyman and Ingason's work; (c) with the coupling effect of ceiling extraction and longitudinal forced air flow, a modified Froude number was proposed to describe the influence of ceiling extraction, and the relation between the smoke thermal stratification and the modified Froude number agree well with Nyman and Ingason's model. … (more)
- Is Part Of:
- Applied thermal engineering. Volume 109:Part A(2016:Sep.)
- Journal:
- Applied thermal engineering
- Issue:
- Volume 109:Part A(2016:Sep.)
- Issue Display:
- Volume 109, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 109
- Issue:
- 1
- Issue Sort Value:
- 2016-0109-0001-0000
- Page Start:
- 312
- Page End:
- 317
- Publication Date:
- 2016-10-25
- Subjects:
- Thermal stratification -- Ceiling extraction -- Tunnel fire -- Longitudinal air velocity -- Froude number
Heat engineering -- Periodicals
Heating -- Equipment and supplies -- Periodicals
Periodicals
621.40205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13594311 ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.applthermaleng.2016.08.071 ↗
- Languages:
- English
- ISSNs:
- 1359-4311
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1580.101000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7519.xml