Comparative evaluation of non-contrast CAIPIRINHA-VIBE 3T-MRI and multidetector CT for detection of pulmonary nodules: In vivo evaluation of diagnostic accuracy and image quality. Issue 1 (January 2016)
- Record Type:
- Journal Article
- Title:
- Comparative evaluation of non-contrast CAIPIRINHA-VIBE 3T-MRI and multidetector CT for detection of pulmonary nodules: In vivo evaluation of diagnostic accuracy and image quality. Issue 1 (January 2016)
- Main Title:
- Comparative evaluation of non-contrast CAIPIRINHA-VIBE 3T-MRI and multidetector CT for detection of pulmonary nodules: In vivo evaluation of diagnostic accuracy and image quality
- Authors:
- Dewes, Patricia
Frellesen, Claudia
Al-Butmeh, Firas
Albrecht, Moritz H.
Scholtz, Jan-Erik
Metzger, Sarah C.
Lehnert, Thomas
Vogl, Thomas J.
Wichmann, Julian L. - Abstract:
- Abstract: Purpose: To evaluate the diagnostic accuracy, subjective image quality, and interobserver agreement of non-contrast Controlled Aliasing In Parallel Imaging Results In Higher Acceleration (CAIPIRINHA) volumetric interpolated breath-hold examination (VIBE) 3T magnetic resonance imaging (MRI) for the detection of pulmonary nodules with intra-individual comparison to computed tomography (CT). Materials and methods: We evaluated 54 patients (27 male, 27 female; mean age, 60.8 ± 11.5 years) who prospectively underwent thoracic 3T-MRI using CAIPIRINHA-VIBE sequences and chest CT. Diagnostic accuracy for the detection of lung nodules on CAIPIRINHA-VIBE MRI by three independent observers were compared to the reference standard CT. Subjective image quality was rated using a 5-point grading scale. Diagnostic accuracy was calculated and interobserver agreement was assessed using intraclass correlation coefficient (ICC). Results: Sensitivity of 3T-MRI for the detection of pulmonary lesions compared to CT was 88.1% (95% confidence interval [CI]: 0.81–0.93) and specifity was 79.1% (95% CI: 0.50–0.95). Sensitivity for lesions <5 mm was 77.2% (95% CI: 0.59–0.90) and for lesions from 5 to 10 mm was 87.2% (95% CI: 0.76–0.94). Sensitivity for lesions >10 mm was 100%. Observer ratings regarding subjective image quality were good to excellent for 3T-MRI (1.54) and CT (1.14) with almost perfect interobserver agreement for 3T-MRI and CT (ICC = 0.83, 95% CI: 0.78–0.89; ICC = 0.89, 95% CI:Abstract: Purpose: To evaluate the diagnostic accuracy, subjective image quality, and interobserver agreement of non-contrast Controlled Aliasing In Parallel Imaging Results In Higher Acceleration (CAIPIRINHA) volumetric interpolated breath-hold examination (VIBE) 3T magnetic resonance imaging (MRI) for the detection of pulmonary nodules with intra-individual comparison to computed tomography (CT). Materials and methods: We evaluated 54 patients (27 male, 27 female; mean age, 60.8 ± 11.5 years) who prospectively underwent thoracic 3T-MRI using CAIPIRINHA-VIBE sequences and chest CT. Diagnostic accuracy for the detection of lung nodules on CAIPIRINHA-VIBE MRI by three independent observers were compared to the reference standard CT. Subjective image quality was rated using a 5-point grading scale. Diagnostic accuracy was calculated and interobserver agreement was assessed using intraclass correlation coefficient (ICC). Results: Sensitivity of 3T-MRI for the detection of pulmonary lesions compared to CT was 88.1% (95% confidence interval [CI]: 0.81–0.93) and specifity was 79.1% (95% CI: 0.50–0.95). Sensitivity for lesions <5 mm was 77.2% (95% CI: 0.59–0.90) and for lesions from 5 to 10 mm was 87.2% (95% CI: 0.76–0.94). Sensitivity for lesions >10 mm was 100%. Observer ratings regarding subjective image quality were good to excellent for 3T-MRI (1.54) and CT (1.14) with almost perfect interobserver agreement for 3T-MRI and CT (ICC = 0.83, 95% CI: 0.78–0.89; ICC = 0.89, 95% CI: 0.85–0.94). Conclusions: Non-contrast CAIPIRINHA-VIBE 3T-MRI allows for the reliable detection of pulmonary lesions with a diameter >5 mm in comparison with chest CT with high diagnostic accuracy, subjective image quality, and interobserver agreement. … (more)
- Is Part Of:
- European journal of radiology. Volume 85:Issue 1(2016)
- Journal:
- European journal of radiology
- Issue:
- Volume 85:Issue 1(2016)
- Issue Display:
- Volume 85, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 85
- Issue:
- 1
- Issue Sort Value:
- 2016-0085-0001-0000
- Page Start:
- 193
- Page End:
- 198
- Publication Date:
- 2016-01
- Subjects:
- CAIPIRINHA Controlled Aliasing In Parallel Imaging Results In Higher Acceleration -- CI confidence interval -- CNR contrast-to-noise ratio -- CT computed tomography -- GFR glomerular filtration rate -- HASTE half-Fourier acquisition single-shot turbo spin-echo -- ICC intraclass correlation coefficient -- MRI magnetic resonance imaging -- pMRI parallel MRI -- SAR signal absorption rates -- SNR signal-to-noise ratio -- VIBE volumetric interpolated breath-hold examination
Solitary pulmonary nodule -- Lung -- Magnetic resonance imaging -- Computed tomography
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2015.11.020 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7508.xml