Dynamic contrast-enhanced perfusion area detector CT for non-small cell lung cancer patients: Influence of mathematical models on early prediction capabilities for treatment response and recurrence after chemoradiotherapy. Issue 1 (January 2016)
- Record Type:
- Journal Article
- Title:
- Dynamic contrast-enhanced perfusion area detector CT for non-small cell lung cancer patients: Influence of mathematical models on early prediction capabilities for treatment response and recurrence after chemoradiotherapy. Issue 1 (January 2016)
- Main Title:
- Dynamic contrast-enhanced perfusion area detector CT for non-small cell lung cancer patients: Influence of mathematical models on early prediction capabilities for treatment response and recurrence after chemoradiotherapy
- Authors:
- Ohno, Yoshiharu
Koyama, Hisanobu
Fujisawa, Yasuko
Yoshikawa, Takeshi
Seki, Shinichiro
Sugihara, Naoki
Sugimura, Kazuro - Abstract:
- Abstract: Purpose: To determine the capability and influence of the mathematical method on dynamic contrast-enhanced (CE-) perfusion area detector CT (ADCT) for early prediction of treatment response as well as progression free and overall survival (PFS and OS) of non-small cell lung cancer (NSCLC) patients treated with chemoradiotherapy. Materials and methods: Sixty-six consecutive stage III NSCLC patients underwent dynamic CE-perfusion ADCT examinations, chemoradiotherapy and follow-up examinations. Response Evaluation Criteria in Solid Tumors (RECIST) criteria were used to divide all patients into responders and non-responders. Differences in each of the indices for all targeted lesions between measurements obtained 2 weeks prior to the first and the third course of chemotherapy were determined for all patients. ROC analyses were employed to determine the capability of perfusion indices as markers for distinguishing RECIST responders from non-responders. To evaluate their capability for early prediction of therapeutic effect, OS of perfusion index-based responders and non-responders were compared by using the Kaplan–Meier method followed by log-rank test. Results: Area under the curve (Az) for total perfusion by means of the dual-input maximum slope method was significantly larger than that of pulmonary arterial perfusion using the same method ( p = 0.007) and of perfusion with the single-input maximum slope method ( p = 0.007). Mean OS demonstrated significantlyAbstract: Purpose: To determine the capability and influence of the mathematical method on dynamic contrast-enhanced (CE-) perfusion area detector CT (ADCT) for early prediction of treatment response as well as progression free and overall survival (PFS and OS) of non-small cell lung cancer (NSCLC) patients treated with chemoradiotherapy. Materials and methods: Sixty-six consecutive stage III NSCLC patients underwent dynamic CE-perfusion ADCT examinations, chemoradiotherapy and follow-up examinations. Response Evaluation Criteria in Solid Tumors (RECIST) criteria were used to divide all patients into responders and non-responders. Differences in each of the indices for all targeted lesions between measurements obtained 2 weeks prior to the first and the third course of chemotherapy were determined for all patients. ROC analyses were employed to determine the capability of perfusion indices as markers for distinguishing RECIST responders from non-responders. To evaluate their capability for early prediction of therapeutic effect, OS of perfusion index-based responders and non-responders were compared by using the Kaplan–Meier method followed by log-rank test. Results: Area under the curve (Az) for total perfusion by means of the dual-input maximum slope method was significantly larger than that of pulmonary arterial perfusion using the same method ( p = 0.007) and of perfusion with the single-input maximum slope method ( p = 0.007). Mean OS demonstrated significantly difference between responder- and non-responder groups for total perfusion ( p = 0.02). Conclusion: Mathematical models have significant influence on assessment for early prediction of treatment response, disease progression and overall survival using dynamic CE-perfusion ADCT for NSCLC patients treated with chemoradiotherapy. … (more)
- Is Part Of:
- European journal of radiology. Volume 85:Issue 1(2016)
- Journal:
- European journal of radiology
- Issue:
- Volume 85:Issue 1(2016)
- Issue Display:
- Volume 85, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 85
- Issue:
- 1
- Issue Sort Value:
- 2016-0085-0001-0000
- Page Start:
- 176
- Page End:
- 186
- Publication Date:
- 2016-01
- Subjects:
- CT -- Perfusion -- Non-small cell lung cancer -- Chemoradiotherapy -- Therapeutic effect
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2015.11.009 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7508.xml