Physicochemical Stability and Sterility of Standard Parenteral Nutrition Solutions and Simulated Y‐Site Admixtures for Neonates. (21st February 2018)
- Record Type:
- Journal Article
- Title:
- Physicochemical Stability and Sterility of Standard Parenteral Nutrition Solutions and Simulated Y‐Site Admixtures for Neonates. (21st February 2018)
- Main Title:
- Physicochemical Stability and Sterility of Standard Parenteral Nutrition Solutions and Simulated Y‐Site Admixtures for Neonates
- Authors:
- Riera, Pau
Garrido‐Alejos, Gemma
Cardenete, Joana
Moliner, Elisenda
Zapico‐Muñiz, Edgar
Cardona, Daniel
Garin, Noe - Abstract:
- Abstract: Background: Parenteral nutrition (PN) is frequently needed in neonatal intensive care. The use of standard PN has emerged as an easy‐to‐prescribe approach that allows one to have on‐site, ready‐to‐use PN. The aim of this study was to test the physicochemical stability and sterility of 2 specific PN solutions as well as simulate Y‐site compatibility with lipid injectable emulsions (ILE). Methods: Our study considered 2 standard ILE–free PN solutions according to neonatal weight. These solutions were prepared in duplicate and stored at 4°C. The following physicochemical parameters were tested: visual alterations, turbidity, pH, osmolarity, and calcium concentration. Sterility was assessed by means of agar blood culture and glucose concentration determination. In addition, we assessed the stability of simulated Y‐site admixtures. For each standard ILE‐free PN solution, 2 3‐in‐1 PN admixtures were designed, considering extreme values of fluid requirements (50 and 150 ml/kg/d) and a fat supply of 2 g/kg/24 h. The physicochemical parameters tested were phase separation and fat mean droplet size distribution. Results: No alterations were detected by visual inspection. Calcium concentrations, turbidity, pH, and osmolarity values remained stable in all the determinations. All agar blood cultures were negative and glucose concentration was constant over time. Physical stability of simulated Y‐site admixtures was considered acceptable as mean droplet size distributionAbstract: Background: Parenteral nutrition (PN) is frequently needed in neonatal intensive care. The use of standard PN has emerged as an easy‐to‐prescribe approach that allows one to have on‐site, ready‐to‐use PN. The aim of this study was to test the physicochemical stability and sterility of 2 specific PN solutions as well as simulate Y‐site compatibility with lipid injectable emulsions (ILE). Methods: Our study considered 2 standard ILE–free PN solutions according to neonatal weight. These solutions were prepared in duplicate and stored at 4°C. The following physicochemical parameters were tested: visual alterations, turbidity, pH, osmolarity, and calcium concentration. Sterility was assessed by means of agar blood culture and glucose concentration determination. In addition, we assessed the stability of simulated Y‐site admixtures. For each standard ILE‐free PN solution, 2 3‐in‐1 PN admixtures were designed, considering extreme values of fluid requirements (50 and 150 ml/kg/d) and a fat supply of 2 g/kg/24 h. The physicochemical parameters tested were phase separation and fat mean droplet size distribution. Results: No alterations were detected by visual inspection. Calcium concentrations, turbidity, pH, and osmolarity values remained stable in all the determinations. All agar blood cultures were negative and glucose concentration was constant over time. Physical stability of simulated Y‐site admixtures was considered acceptable as mean droplet size distribution remained below 500 nm in all the emulsions. Conclusion: The 2 tested standard ILE‐free PN solutions for neonates are physicochemically stable and sterile for 31 days under refrigeration (4°C). These solutions are also stable in case of Y‐site administration with ILE at the conditions tested. … (more)
- Is Part Of:
- Nutrition in clinical practice. Volume 33:Number 5(2018:Oct.)
- Journal:
- Nutrition in clinical practice
- Issue:
- Volume 33:Number 5(2018:Oct.)
- Issue Display:
- Volume 33, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 33
- Issue:
- 5
- Issue Sort Value:
- 2018-0033-0005-0000
- Page Start:
- 694
- Page End:
- 700
- Publication Date:
- 2018-02-21
- Subjects:
- neonates -- parenteral nutrition -- sterility -- stability lipid injectable emulsions -- newborn infant; intravenous fat emulsions; parenteral nutrition solutions; safety; drug stability
Nutrition -- Periodicals
Diet therapy -- Periodicals
Artificial feeding -- Periodicals
615.854 - Journal URLs:
- http://ncp.aspenjournals.org ↗
http://ncp.sagepub.com ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1002/ncp.10013 ↗
- Languages:
- English
- ISSNs:
- 0884-5336
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6188.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7517.xml