Electroanatomic mapping‐guided localization of alternative right ventricular septal pacing sites in children. Issue 9 (9th August 2018)
- Record Type:
- Journal Article
- Title:
- Electroanatomic mapping‐guided localization of alternative right ventricular septal pacing sites in children. Issue 9 (9th August 2018)
- Main Title:
- Electroanatomic mapping‐guided localization of alternative right ventricular septal pacing sites in children
- Authors:
- Silvetti, Massimo Stefano
Battipaglia, Irma
Pazzano, Vincenzo
Saputo, Fabio Anselmo
Ravà, Lucilla
Ammirati, Antonio
Calvieri, Camilla
Ciani, Michele
Drago, Fabrizio - Abstract:
- Abstract: Background: Alternative right ventricular (RV) sites (RVAPS) have been proposed to prevent or reduce RV pacing‐induced left‐ventricular (LV) dysfunction. Nonfluoroscopic 3D electroanatomic mapping systems (EAM) have been developed to guide cardiac catheter navigation and reduce fluoroscopy during electrophysiological procedures or pacemaker implantations. Aim: The aim of the study was to compare the results of EAM‐guided permanent pacemaker implantation aiming at RVAPS with conventional fluoroscopic‐guided implantation in RV apex (RVA) in children and adolescents. Methods: A prospective, randomized analysis was performed on children/adolescents with complete atrioventricular block (CAVB) who underwent EAM‐guided pacemaker and transvenous leads implantation into RVAPS (EAM‐RVAPS) or conventional, fluoroscopic‐guided implantation into RV apex (RVA). In EAM‐RVAPS, a pacing map guided the implantation of ventricular leads in septal sites with narrower QRS. After implantation, LV contractility (ejection fraction [EF], Global Longitudinal Strain [GLS]) and synchrony were evaluated at 1–12 months. Results: Twenty‐one pediatric patients with CAVB, with (six patients) or without structural heart diseases, aged 4–16 (median 10.5) years, were divided in two groups: EAM‐RVAPS (11 patients, four dual‐chamber/DDD, seven single‐chamber/VVIR pacemakers) and RVA (10 patients, one DDD/nine VVIR). The two groups did not show significant differences for preoperative parameters.Abstract: Background: Alternative right ventricular (RV) sites (RVAPS) have been proposed to prevent or reduce RV pacing‐induced left‐ventricular (LV) dysfunction. Nonfluoroscopic 3D electroanatomic mapping systems (EAM) have been developed to guide cardiac catheter navigation and reduce fluoroscopy during electrophysiological procedures or pacemaker implantations. Aim: The aim of the study was to compare the results of EAM‐guided permanent pacemaker implantation aiming at RVAPS with conventional fluoroscopic‐guided implantation in RV apex (RVA) in children and adolescents. Methods: A prospective, randomized analysis was performed on children/adolescents with complete atrioventricular block (CAVB) who underwent EAM‐guided pacemaker and transvenous leads implantation into RVAPS (EAM‐RVAPS) or conventional, fluoroscopic‐guided implantation into RV apex (RVA). In EAM‐RVAPS, a pacing map guided the implantation of ventricular leads in septal sites with narrower QRS. After implantation, LV contractility (ejection fraction [EF], Global Longitudinal Strain [GLS]) and synchrony were evaluated at 1–12 months. Results: Twenty‐one pediatric patients with CAVB, with (six patients) or without structural heart diseases, aged 4–16 (median 10.5) years, were divided in two groups: EAM‐RVAPS (11 patients, four dual‐chamber/DDD, seven single‐chamber/VVIR pacemakers) and RVA (10 patients, one DDD/nine VVIR). The two groups did not show significant differences for preoperative parameters. EAM‐RVAPS showed: preserved LVEF and synchrony (not significantly different than RVA), significantly lower GLS and radiation doses/exposures, in spite more complex procedures, significantly longer procedure times and narrower paced QRS than RVA. Conclusions: EAM‐guided procedures have been useful to reduce radiation exposure and to localize RVAPS with narrower paced QRS and lower GLS than RVA. … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 41:Issue 9(2018)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 41:Issue 9(2018)
- Issue Display:
- Volume 41, Issue 9 (2018)
- Year:
- 2018
- Volume:
- 41
- Issue:
- 9
- Issue Sort Value:
- 2018-0041-0009-0000
- Page Start:
- 1204
- Page End:
- 1211
- Publication Date:
- 2018-08-09
- Subjects:
- alternative pacing sites -- cardiac pacing -- nonfluoroscopic mapping system -- pediatric age -- radiation exposure
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.13447 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7519.xml