Effects of coping designs on fracture modes in zirconia crowns: Progressive load test. Issue 6 (1st May 2016)
- Record Type:
- Journal Article
- Title:
- Effects of coping designs on fracture modes in zirconia crowns: Progressive load test. Issue 6 (1st May 2016)
- Main Title:
- Effects of coping designs on fracture modes in zirconia crowns: Progressive load test
- Authors:
- Ha, Seung-Ryong
Kim, Sung-Hun
Lee, Jai-Bong
Han, Jung-Suk
Yeo, In-Sung - Abstract:
- Abstract: This study was designed to evaluate the effects of different coping designs on the fracture modes of posterior zirconia crowns. One hundred mandibular molar copings of ten different designs were fabricated from 3Y-TZP. All ten different groups ( n =10) had 1 mm wide shoulder, but they had varying heights of 1 mm, 2 mm, or 3 mm on the buccal, lingual and proximal sides. After being sintered and veneered, the zirconia crowns on titanium abutments were stored in distilled water at 37 °C for 24 h. Then they were loaded into a universal testing machine. The veneer fracture load and bulk fracture load values were measured. Moreover, the fracture surfaces were examined with a scanning electron microscope. One-way analysis of variance and the Scheffé posthoc test were carried out for statistical analyses ( α =.05). Higher shoulders on the buccal, lingual and proximal sides resulted in higher fracture load values. As the heights of the shoulders increased, the occurrence of chipping decreased. Additionally, the bulk fractures on the buccal surfaces increased in the crowns with higher shoulders. We concluded that the shoulder coping design plays a critical role in the survival of posterior zirconia restorations by reducing veneering porcelain fractures.
- Is Part Of:
- Ceramics international. Volume 42:Issue 6(2016)
- Journal:
- Ceramics international
- Issue:
- Volume 42:Issue 6(2016)
- Issue Display:
- Volume 42, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 42
- Issue:
- 6
- Issue Sort Value:
- 2016-0042-0006-0000
- Page Start:
- 7380
- Page End:
- 7389
- Publication Date:
- 2016-05-01
- Subjects:
- Failure analysis -- Fracture -- Dental prosthesis design -- Stress -- Zirconium
Ceramics -- Periodicals
Céramique industrielle -- Périodiques
Ceramics
Periodicals
Electronic journals
666 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02728842 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ceramint.2016.01.141 ↗
- Languages:
- English
- ISSNs:
- 0272-8842
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3119.015000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7487.xml