A transient quasi-3D entire time scale line source model for the fluid and ground temperature prediction of vertical ground heat exchangers (GHEs). (15th May 2016)
- Record Type:
- Journal Article
- Title:
- A transient quasi-3D entire time scale line source model for the fluid and ground temperature prediction of vertical ground heat exchangers (GHEs). (15th May 2016)
- Main Title:
- A transient quasi-3D entire time scale line source model for the fluid and ground temperature prediction of vertical ground heat exchangers (GHEs)
- Authors:
- Zhang, Linfeng
Zhang, Quan
Huang, Gongsheng - Abstract:
- Highlights: The proposed model can accurately predict fluid and ground temperature. The relative error of the fluid temperature prediction is less than 5%. The maximum relative error of the ground temperature prediction is 3.85%. The heat flux profile is important for borehole distance determination. Abstract: The energy performance of Ground-Coupled Heat Pump systems (GCHPs) depends heavily on the fluid temperature over the entire time scale inside the ground heat exchangers (GHEs) and the ground temperature profile outside the borehole. These temperatures define not only the coefficient of performance (COP) of GCHPs but also the ground receptivity of the energy demand of buildings. Although GCHPs have been studied for many years, it is still a great challenge to develop a model that can accurately predict both short-term and long-term responses due to the complex borehole configuration and the thermal capacity of grout. A new transient quasi-3D entire time scale line source model is proposed in this paper, which introduces the concept of transient borehole thermal resistance and considers the heat flux profile along the U-pipe as a variable. The proposed model is firstly compared with several existent models, including several traditional line source models and a full scale response model, using the data collected from a reported Sandbox experiment. The comparison study shows that the proposed model is able to predict the temperature with a relative error less than 5%.Highlights: The proposed model can accurately predict fluid and ground temperature. The relative error of the fluid temperature prediction is less than 5%. The maximum relative error of the ground temperature prediction is 3.85%. The heat flux profile is important for borehole distance determination. Abstract: The energy performance of Ground-Coupled Heat Pump systems (GCHPs) depends heavily on the fluid temperature over the entire time scale inside the ground heat exchangers (GHEs) and the ground temperature profile outside the borehole. These temperatures define not only the coefficient of performance (COP) of GCHPs but also the ground receptivity of the energy demand of buildings. Although GCHPs have been studied for many years, it is still a great challenge to develop a model that can accurately predict both short-term and long-term responses due to the complex borehole configuration and the thermal capacity of grout. A new transient quasi-3D entire time scale line source model is proposed in this paper, which introduces the concept of transient borehole thermal resistance and considers the heat flux profile along the U-pipe as a variable. The proposed model is firstly compared with several existent models, including several traditional line source models and a full scale response model, using the data collected from a reported Sandbox experiment. The comparison study shows that the proposed model is able to predict the temperature with a relative error less than 5%. Then, the outside ground temperature profile that defines the borehole distance is analyzed and compared with the Sandbox experiment result, which shows that the proposed model leads to a maximum relative error being less than 3.85%. Finally, the impact of the heat flux profile along the U-pipe on the ground temperature profile prediction is investigated, which shows that when the heat flux profile along the U-pipe is considered as a variable, the determination of borehole distance will be much more accurate. Therefore, the transient quasi-3D entire time scale line source model is an effective method for the fluid and ground temperature prediction and may offer the theoretical basis for the system control and the borehole distance determination. … (more)
- Is Part Of:
- Applied energy. Volume 170(2016)
- Journal:
- Applied energy
- Issue:
- Volume 170(2016)
- Issue Display:
- Volume 170, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 170
- Issue:
- 2016
- Issue Sort Value:
- 2016-0170-2016-0000
- Page Start:
- 65
- Page End:
- 75
- Publication Date:
- 2016-05-15
- Subjects:
- Transient borehole thermal resistance -- Transient quasi-3D entire time scale line source model -- Ground-Coupled Heat Pump systems -- Fluid temperature prediction -- Heat flux
Power (Mechanics) -- Periodicals
Energy conservation -- Periodicals
Energy conversion -- Periodicals
621.042 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03062619 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apenergy.2016.02.099 ↗
- Languages:
- English
- ISSNs:
- 0306-2619
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1572.300000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7460.xml