Application of Digital Image Analysis to Determine Pancreatic Islet Mass and Purity in Clinical Islet Isolation and Transplantation. Issue 7 (July 2015)
- Record Type:
- Journal Article
- Title:
- Application of Digital Image Analysis to Determine Pancreatic Islet Mass and Purity in Clinical Islet Isolation and Transplantation. Issue 7 (July 2015)
- Main Title:
- Application of Digital Image Analysis to Determine Pancreatic Islet Mass and Purity in Clinical Islet Isolation and Transplantation
- Authors:
- Wang, Ling-Jia
Kissler, Hermann J.
Wang, Xiaojun
Cochet, Olivia
Krzystyniak, Adam
Misawa, Ryosuke
Golab, Karolina
Tibudan, Martin
Grzanka, Jakub
Savari, Omid
Kaufman, Dixon B.
Millis, Michael
Witkowski, Piotr - Abstract:
- Pancreatic islet mass, represented by islet equivalent (IEQ), is the most important parameter in decision making for clinical islet transplantation. To obtain IEQ, the sample of islets is routinely counted under a microscope and discarded thereafter. Islet purity, another parameter in islet processing, is routinely assessed by estimation only. In this study, we validated our digital image analysis (DIA) system by using the software of Image Pro Plus and a custom-designed Excel template to assess islet mass and purity to better comply with current good manufacturing practice (cGMP) standards. Human islet samples (60 collected from a single isolation and 24 collected from 12 isolations) were captured as calibrated digital images for the permanent record. Seven trained technicians participated in determination of IEQ and purity by the manual counting method (manual image counting, Manual I) and DIA. IEQ count showed statistically significant correlations between the Manual I and DIA in all sample comparisons ( r > 0.819 and p < 0.0001). A statistically significant difference in IEQ between Manual I and DIA was not found in all sample groups ( p > 0.05). In terms of purity determination, statistically significant differences between assessment and DIA measurement were found in high-purity 100-μl samples ( p < 0.005) and low-purity 100-μl samples ( p < 0.001) of the single isolation. In addition, islet particle number (IPN) and the IEQ/IPN ratio did not differ statisticallyPancreatic islet mass, represented by islet equivalent (IEQ), is the most important parameter in decision making for clinical islet transplantation. To obtain IEQ, the sample of islets is routinely counted under a microscope and discarded thereafter. Islet purity, another parameter in islet processing, is routinely assessed by estimation only. In this study, we validated our digital image analysis (DIA) system by using the software of Image Pro Plus and a custom-designed Excel template to assess islet mass and purity to better comply with current good manufacturing practice (cGMP) standards. Human islet samples (60 collected from a single isolation and 24 collected from 12 isolations) were captured as calibrated digital images for the permanent record. Seven trained technicians participated in determination of IEQ and purity by the manual counting method (manual image counting, Manual I) and DIA. IEQ count showed statistically significant correlations between the Manual I and DIA in all sample comparisons ( r > 0.819 and p < 0.0001). A statistically significant difference in IEQ between Manual I and DIA was not found in all sample groups ( p > 0.05). In terms of purity determination, statistically significant differences between assessment and DIA measurement were found in high-purity 100-μl samples ( p < 0.005) and low-purity 100-μl samples ( p < 0.001) of the single isolation. In addition, islet particle number (IPN) and the IEQ/IPN ratio did not differ statistically between Manual I and DIA. In conclusion, the DIA used in this study is a reliable technique to determine IEQ and purity. Islet sample preserved as a digital image and results produced by DIA can be permanently stored for verification, technical training, and information exchange among islet centers. Therefore, DIA complies better with cGMP requirements than the manual counting method. We propose DIA as a quality control tool to supplement the established standard manual method for islet counting and purity estimation. … (more)
- Is Part Of:
- Cell transplantation. Volume 24:Issue 7(2015)
- Journal:
- Cell transplantation
- Issue:
- Volume 24:Issue 7(2015)
- Issue Display:
- Volume 24, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 24
- Issue:
- 7
- Issue Sort Value:
- 2015-0024-0007-0000
- Page Start:
- 1195
- Page End:
- 1204
- Publication Date:
- 2015-07
- Subjects:
- Digital image analysis (DIA) -- Islet quantification -- Islet purity -- Islet transplantation
Cell transplantation -- Periodicals
Cell Transplantation
Cell transplantation
Electronic journals
Periodicals
Periodicals
571.638 - Journal URLs:
- http://journals.sagepub.com/home/cll ↗
http://www.sagepublications.com/ ↗
http://www.cognizantcommunication.com ↗ - DOI:
- 10.3727/096368914X681612 ↗
- Languages:
- English
- ISSNs:
- 0963-6897
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7474.xml