Air density dependence of the PTW 34013 ionization chamber for soft X-ray. (September 2016)
- Record Type:
- Journal Article
- Title:
- Air density dependence of the PTW 34013 ionization chamber for soft X-ray. (September 2016)
- Main Title:
- Air density dependence of the PTW 34013 ionization chamber for soft X-ray
- Authors:
- del Río, J. Torres
Forastero, C.
Tornero-López, A.M.
de la Vega, J.M.
Guirado, D.
Pérez-Calatayud, J.
Lallena, A.M. - Abstract:
- Abstract : Introduction: It has been proved that some ionization chambers, when measuring low energy brachytherapy or soft X-ray sources, show a dependence with the air density that it is not entirely corrected with the usual pressure/temperature correction factor, k TP . This is due to the chamber dimensions and materials forming it. Purpose: To determine if the response of PTW 34013 chamber, used for dose measurements in superficial radiotherapy, is fully corrected with k TP or a residual air density dependence remains. Materials and methods: Measurements for 70 and 200 kVp X-ray beams, generated by a MAXISHOT.200 cabinet, have been performed using a pressurized chamber. Raw data have been corrected with k TP and normalized to its value in standard atmospheric conditions (760 mmHg and 20 °C). Results: The corrected measurements for both beams still show a linear dependence with the normalized density ρ / ρ 0, ρ 0 being the density in standard atmospheric conditions. When the air density is below ρ 0, k TP undercorrects the measurement, and the contrary occurs when ρ > ρ 0 . In our city, with 700 m AMSL, usual atmospheric conditions will cause 1.2% undercorrection for the 70 kV beam and 2.5% for the 200 kV beam. Conclusion: Despite its dimensions, the dependence of the PTW 34013 ionization chamber with the air density is not fully corrected with k TP . The weather or the altitude of the place where measurements are carried out will require an additional correction toAbstract : Introduction: It has been proved that some ionization chambers, when measuring low energy brachytherapy or soft X-ray sources, show a dependence with the air density that it is not entirely corrected with the usual pressure/temperature correction factor, k TP . This is due to the chamber dimensions and materials forming it. Purpose: To determine if the response of PTW 34013 chamber, used for dose measurements in superficial radiotherapy, is fully corrected with k TP or a residual air density dependence remains. Materials and methods: Measurements for 70 and 200 kVp X-ray beams, generated by a MAXISHOT.200 cabinet, have been performed using a pressurized chamber. Raw data have been corrected with k TP and normalized to its value in standard atmospheric conditions (760 mmHg and 20 °C). Results: The corrected measurements for both beams still show a linear dependence with the normalized density ρ / ρ 0, ρ 0 being the density in standard atmospheric conditions. When the air density is below ρ 0, k TP undercorrects the measurement, and the contrary occurs when ρ > ρ 0 . In our city, with 700 m AMSL, usual atmospheric conditions will cause 1.2% undercorrection for the 70 kV beam and 2.5% for the 200 kV beam. Conclusion: Despite its dimensions, the dependence of the PTW 34013 ionization chamber with the air density is not fully corrected with k TP . The weather or the altitude of the place where measurements are carried out will require an additional correction to reach the accuracy level required in radiotherapy. Disclosure: We thank to PTW for material support. … (more)
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 3
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 3
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- 219
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.07.736 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7457.xml