A new robust statistical method for treatment planning systems validation using experimental designs. (September 2016)
- Record Type:
- Journal Article
- Title:
- A new robust statistical method for treatment planning systems validation using experimental designs. (September 2016)
- Main Title:
- A new robust statistical method for treatment planning systems validation using experimental designs
- Authors:
- Dufreneix, S.
Briand, K.
Di Bartolo, C.
Legrand, C.
Bremaud, M.
Mesgouez, J.
Tiplica, T.
Autret, D. - Abstract:
- Abstract : Introduction: Dose computation verification is an important part of acceptance testing. The IAEA Tecdoc 1540 and 1583 suggest comparing computed dose to measurements for several beam configurations. However, this process is time-consuming and results out of tolerance are often left unexplained. Purpose: To validate a treatment planning system using experimental designs which allow evaluating several parameters in a few tests selected by a robust statistical method. Materials and methods: The Taguchi table L36 (2 11 × 3 12 ) was used to determine the 72 beams needed to test the 7 parameters chosen: energy, MLC, depth, jaw field size in X, Y1 and Y2 directions and wedge. Measurements were conducted in water using a CC04 (IBA) on a TrueBeam STx, a TrueBeam Tx, a Trilogy and a C-serie clinac (Varian). Dose was computed using the AAA algorithm (Eclipse, version 11). The same raw data was used for all accelerators during the algorithm configuration. Results: The mean difference between computed and measured doses was 0.1 ± 0.5% for all tested beams and all linacs with a maximum difference of 2.4% (under the 3% tolerance level). For all beams, the measured doses were within 0.6% for all linacs. No studied parameter led to statistically significant deviation between computed and measured doses. Conclusion: Experimental design is a robust statistical method to validate an algorithm. Only 2 h of measurements were needed to evaluate 7 parameters. Furthermore, theAbstract : Introduction: Dose computation verification is an important part of acceptance testing. The IAEA Tecdoc 1540 and 1583 suggest comparing computed dose to measurements for several beam configurations. However, this process is time-consuming and results out of tolerance are often left unexplained. Purpose: To validate a treatment planning system using experimental designs which allow evaluating several parameters in a few tests selected by a robust statistical method. Materials and methods: The Taguchi table L36 (2 11 × 3 12 ) was used to determine the 72 beams needed to test the 7 parameters chosen: energy, MLC, depth, jaw field size in X, Y1 and Y2 directions and wedge. Measurements were conducted in water using a CC04 (IBA) on a TrueBeam STx, a TrueBeam Tx, a Trilogy and a C-serie clinac (Varian). Dose was computed using the AAA algorithm (Eclipse, version 11). The same raw data was used for all accelerators during the algorithm configuration. Results: The mean difference between computed and measured doses was 0.1 ± 0.5% for all tested beams and all linacs with a maximum difference of 2.4% (under the 3% tolerance level). For all beams, the measured doses were within 0.6% for all linacs. No studied parameter led to statistically significant deviation between computed and measured doses. Conclusion: Experimental design is a robust statistical method to validate an algorithm. Only 2 h of measurements were needed to evaluate 7 parameters. Furthermore, the commissioned accelerators were found dosimetrically equivalent even though the linac characteristics differ. Disclosure: No disclosure. … (more)
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 3
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 3
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- 202
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.07.684 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7457.xml