Implementation of the EFOMP protocol for quality control in digital mammography in a multi-hospital/vendor context. (September 2016)
- Record Type:
- Journal Article
- Title:
- Implementation of the EFOMP protocol for quality control in digital mammography in a multi-hospital/vendor context. (September 2016)
- Main Title:
- Implementation of the EFOMP protocol for quality control in digital mammography in a multi-hospital/vendor context
- Authors:
- A.Savini,
Bartolucci, F.
Fidanza, C.
Rosica, F.
Capone, F.
Orlandi, G. - Abstract:
- Abstract : Introduction: The European Federation of Organisations in Medical Physics (EFOMP) has recently released a protocol for quality control (QC) in digital mammography with the intent of harmonizing and simplifying the QC procedures across the European countries. Purpose: The aim of this work was to report our experience regarding the implementation of the EFOMP protocol for QC in digital mammography in a multi-hospital/vendor context. Materials and methods: QC tests suggested by the EFOMP protocol were merged with mandatory tests by national (Italian) regulations in order to build a local QC protocol. The protocol was applied to one DR and three CR mammography systems developed by different vendors. Time needed for routine QCs was measured. A fast weekly test was implemented to assess the long term reproducibility of relevant quantities (dose and SNR). Results: By employing one physicist and one technologist, the time needed for routine QC was: 4.5 h ± 0.5 h (annual tests), 2.5 h ± 0.5 h (semiannual tests), 0.2 h ± 0.1 h (weekly tests). For weekly tests, coefficients of variation of dose and SNR were below 6.0% (four-months period evaluated). By applying the developed protocol, two major and five minor anomalies were identified and corrected. Conclusions: The EFOMP protocol could be adapted to local (Italian) regulations with minor modifications. Flexibility and simplification of routine QCs were advantageous in a busy multi-hospital/vendor context. Disclosure: None.
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 3
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 3
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- 279
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.07.622 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7457.xml