A MC study on the eye lens dose distribution for medical staff in interventional radiology. (September 2016)
- Record Type:
- Journal Article
- Title:
- A MC study on the eye lens dose distribution for medical staff in interventional radiology. (September 2016)
- Main Title:
- A MC study on the eye lens dose distribution for medical staff in interventional radiology
- Authors:
- Zagorska, Anna
Bliznakova, Kristina
Trianni, Annalisa
Vassileva, Jenia - Abstract:
- Abstract : Introduction: Recent studies showed equivalent dose at a depth of 0.07 mm, Hp (0.07) to be adequate in some cases to monitor the eye lens in interventional radiology, instead of equivalent dose at a depth of 3 mm, Hp (3). Purpose: The aim of this study was to investigate by Monte Carlo calculations the dose deposition within the eye lens and contribute to the choice of the appropriate dose quantity. Materials and methods: The XRayImagingSimulator was used to model the patient, the operator and the interventional diagnostic unit as well as to calculate the dose within the operators eyes by use of Monte Carlo techniques. Eye lens were placed in three different depths within the eye: 2.3 mm, 3.3 mm, 4.3 mm, representing mean depth and the limits found in a normal adult population. The primary spectra were calculated for 70 kV tube voltage, 12° tungsten target, 3 mm aluminum inherent filtration with an additional copper filtration (0.1 mm, 0.3 mm, 0.6 mm, 0.9 mm) according to IPEM 78 Publication. Results: The calculated total absorbed dose in the eye lens depends on the initial incident spectra. This quantity normalized to the eye dose, is between 1.8% and 2.3% in the studied cases and increases with increasing the depth of the eye lens' location. Comparison to experimental data is also provided. Conclusions: The equivalent dose at a depth of 3 mm Hp (3) is likely to be the appropriate quantity for the best estimate of the eye lens dose.
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 3
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 3
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- 260
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.07.560 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7456.xml