Correction factors for the IBA razor diode for output factor measurements in perfexion gamma knife system. (September 2016)
- Record Type:
- Journal Article
- Title:
- Correction factors for the IBA razor diode for output factor measurements in perfexion gamma knife system. (September 2016)
- Main Title:
- Correction factors for the IBA razor diode for output factor measurements in perfexion gamma knife system
- Authors:
- Yakoumakis, N.
Kollias, G.
Paraskevopoulou, C.
Koutsouveli, E.
Karaiskos, P. - Abstract:
- Abstract : Introduction: A new formalism has been recently proposed for the dosimetry of small and non-standard fields. In terms of output factor (OF) measurements, a correction factor k(Q(clin), Q(msr)) (f(clin), f(msr)) is introduced, that accounts for differences in the detectors response in a given clinical field, f(clin), with regard to the machine-specific reference field, f(msr). Purpose: To derive these correction factors for the 4 mm and 8 mm collimators of Perfexion Leksell gamma knife (LGK) system for the new Razor diode detector providing by IBA for small filed dosimetry. Materials and methods: In Perfexion system, f(msr) is defined by the 16 mm collimator. OF measurements were performed for the 4 mm and 8 mm collimators (f(clin)), using the solid water, 16 cm in diameter LGK dosimetry phantom, along with a custom made insert facilitating accurate detector positioning. The k(Q(clin), Q(msr)) (f(clin), f(msr)) factor of the Razor diode detector was determined, by comparing the ratio of detector readings in f(clin) (4 mm and 8 mm collimators) and f(msr) (16 mm collimator) to corresponding MC reference OF data. Results: Razor diode was found to slightly overestimate both f(clin) OFs with overestimation being greater for the smaller 4 mm collimator reaching up to 4% and almost negligible (<0.6%) for the 8 mm collimator. Conclusion: IBA Razor diode can be safely used for OF measurements in gamma knife perfexion system. However, a correction of the order of 4% must beAbstract : Introduction: A new formalism has been recently proposed for the dosimetry of small and non-standard fields. In terms of output factor (OF) measurements, a correction factor k(Q(clin), Q(msr)) (f(clin), f(msr)) is introduced, that accounts for differences in the detectors response in a given clinical field, f(clin), with regard to the machine-specific reference field, f(msr). Purpose: To derive these correction factors for the 4 mm and 8 mm collimators of Perfexion Leksell gamma knife (LGK) system for the new Razor diode detector providing by IBA for small filed dosimetry. Materials and methods: In Perfexion system, f(msr) is defined by the 16 mm collimator. OF measurements were performed for the 4 mm and 8 mm collimators (f(clin)), using the solid water, 16 cm in diameter LGK dosimetry phantom, along with a custom made insert facilitating accurate detector positioning. The k(Q(clin), Q(msr)) (f(clin), f(msr)) factor of the Razor diode detector was determined, by comparing the ratio of detector readings in f(clin) (4 mm and 8 mm collimators) and f(msr) (16 mm collimator) to corresponding MC reference OF data. Results: Razor diode was found to slightly overestimate both f(clin) OFs with overestimation being greater for the smaller 4 mm collimator reaching up to 4% and almost negligible (<0.6%) for the 8 mm collimator. Conclusion: IBA Razor diode can be safely used for OF measurements in gamma knife perfexion system. However, a correction of the order of 4% must be used for accurate determination of the smallest 4 mm collimator. … (more)
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 3
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 3
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- 272
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.07.598 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7456.xml