Epid-based in vivo dosimetry for complex VMAT treatments dose verification in clinical routine. (September 2016)
- Record Type:
- Journal Article
- Title:
- Epid-based in vivo dosimetry for complex VMAT treatments dose verification in clinical routine. (September 2016)
- Main Title:
- Epid-based in vivo dosimetry for complex VMAT treatments dose verification in clinical routine
- Authors:
- Cilla, Savino
Ianiro, Anna
Deodato, Francesco
Macchia, Gabriella
Fidanzio, Andrea
Azario, Luigi
Valentini, Vincenzo
Morganti, Alessio G.
Piermattei, Angelo - Abstract:
- Abstract : Introduction: Due to the increasing complexity of radiotherapy treatments, comprehensive quality assurance programs are mandatory to check the proper functioning of the whole radiotherapy chain. In vivo dosimetry (IVD), a direct method of measuring radiation doses to cancer patients during treatment, has shown unique features to trace deviations between planned and actually delivered dose distributions. Purpose: To assess the usefulness of EPID-based IVD for complex VMAT treatments in clinical routine. Materials and methods: 80 patients (30 with head-neck tumor, 30 with pelvic tumors and 20 patients with extracranial metastases) treated with Elekta were enrolled. IVD tests were evaluate by means of (i) R ratio between daily in-vivo isocenter dose and planned dose and (ii) γ -analysis between EPID integral portal images in terms of percentage of points with γ -value smaller than one ( γ %) and mean γ -values ( γ mean), using a global 3%-3 mm criteria. Alert criteria of ±5% for R ratio, γ % <90% and γ mean >0.67 were chosen. Results: A total of 980 transit EPID images were acquired. The mean R ratio was equal to 1.001 ± 0.015 for all patients with more than 95% of tests were within 5%. For HN, pelvic and SBRT treatments, γ % and γ mean metrics reported 85.9%, 83.1% and 95.4%, and 93.3%, 92.1% and 98.1% of tests within alert criteria, respectively. The systematic use of IVD revealed relevant discrepancies in a few H–N patients due to major anatomical variations andAbstract : Introduction: Due to the increasing complexity of radiotherapy treatments, comprehensive quality assurance programs are mandatory to check the proper functioning of the whole radiotherapy chain. In vivo dosimetry (IVD), a direct method of measuring radiation doses to cancer patients during treatment, has shown unique features to trace deviations between planned and actually delivered dose distributions. Purpose: To assess the usefulness of EPID-based IVD for complex VMAT treatments in clinical routine. Materials and methods: 80 patients (30 with head-neck tumor, 30 with pelvic tumors and 20 patients with extracranial metastases) treated with Elekta were enrolled. IVD tests were evaluate by means of (i) R ratio between daily in-vivo isocenter dose and planned dose and (ii) γ -analysis between EPID integral portal images in terms of percentage of points with γ -value smaller than one ( γ %) and mean γ -values ( γ mean), using a global 3%-3 mm criteria. Alert criteria of ±5% for R ratio, γ % <90% and γ mean >0.67 were chosen. Results: A total of 980 transit EPID images were acquired. The mean R ratio was equal to 1.001 ± 0.015 for all patients with more than 95% of tests were within 5%. For HN, pelvic and SBRT treatments, γ % and γ mean metrics reported 85.9%, 83.1% and 95.4%, and 93.3%, 92.1% and 98.1% of tests within alert criteria, respectively. The systematic use of IVD revealed relevant discrepancies in a few H–N patients due to major anatomical variations and variations due to random anatomical changes in terms of filling of rectum/bladder in pelvic tumors. No discrepancies were detected in SBRT patients. Conclusion: IVD was able to detect when delivery was inconsistent with the original plans, allowing physics and medical staff to promptly act in case of major deviations. … (more)
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 3
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 3
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- 254
- Page End:
- 255
- Publication Date:
- 2016-09
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.07.545 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7455.xml