Monte carlo determination of correction factors for dosimetric measurements in gamma knife perfexion small fields. (September 2016)
- Record Type:
- Journal Article
- Title:
- Monte carlo determination of correction factors for dosimetric measurements in gamma knife perfexion small fields. (September 2016)
- Main Title:
- Monte carlo determination of correction factors for dosimetric measurements in gamma knife perfexion small fields
- Authors:
- Zoros, E.
Pappas, E.P.
Moutsatsos, A.
Pantelis, E.
Paraskevopoulou, C.
Georgiou, E.
Karaiskos, P. - Abstract:
- Abstract : Introduction: In the formalism proposed by Alfonso et al . (2008) for the dosimetry of small and non-standard photon fields, Monte Carlo (MC) simulation is indicated as a proper means for determining machine-specific reference field ( k Q msr, Q f msr, f ref ) and clinical radiation fields ( k Q clin, Q msr f clin, f msr ) correction factors (CFs) assigned to calibration and relative dosimetry measurements, respectively. Purpose: To determine CFs for the Gamma Knife Perfexion (PFX) radiosurgery unit for a variety of commercially available detectors utilizing MC simulations. Materials and methods: A recently introduced EGSnrc comprehensive simulation model for the PFX irradiation unit was used. A set of 13 ionization chambers, 6 diodes detectors, TLD microcubes and alanine pellets were simulated based on blueprints provided by the vendors. CFs calculations were performed using the egs_chamber user code. Intermediate Phase Space Scoring and photon cross section enhancement variance reduction techniques were implemented in order to increase time efficiency. MC calculations were performed by a super-computer consisting of 8520 computational threads achieving a combined statistical uncertainty of 0.3%. Results: Calculated k Q msr, Q f msr, f ref for ionization chambers commonly used for reference dosimetry in PFX were up to 1.02 (IBA-CC01). Calculations for k Q clin, Q msr f clin, f msr revealed an overestimation of diode detectors up to 6% for the 4mm-collimator,Abstract : Introduction: In the formalism proposed by Alfonso et al . (2008) for the dosimetry of small and non-standard photon fields, Monte Carlo (MC) simulation is indicated as a proper means for determining machine-specific reference field ( k Q msr, Q f msr, f ref ) and clinical radiation fields ( k Q clin, Q msr f clin, f msr ) correction factors (CFs) assigned to calibration and relative dosimetry measurements, respectively. Purpose: To determine CFs for the Gamma Knife Perfexion (PFX) radiosurgery unit for a variety of commercially available detectors utilizing MC simulations. Materials and methods: A recently introduced EGSnrc comprehensive simulation model for the PFX irradiation unit was used. A set of 13 ionization chambers, 6 diodes detectors, TLD microcubes and alanine pellets were simulated based on blueprints provided by the vendors. CFs calculations were performed using the egs_chamber user code. Intermediate Phase Space Scoring and photon cross section enhancement variance reduction techniques were implemented in order to increase time efficiency. MC calculations were performed by a super-computer consisting of 8520 computational threads achieving a combined statistical uncertainty of 0.3%. Results: Calculated k Q msr, Q f msr, f ref for ionization chambers commonly used for reference dosimetry in PFX were up to 1.02 (IBA-CC01). Calculations for k Q clin, Q msr f clin, f msr revealed an overestimation of diode detectors up to 6% for the 4mm-collimator, while CFs for ionization chambers (active volume ⩽0.04cm 3 ) reached 1.48 (PTW-31015). Conclusion: A set of CFs were determined for the PFX unit allowing for more accurate dosimetry measurements. Disclosure: This work was supported by computational time granted from the Greek Research & Technology Network (GRNET) in the National HPC facility -ARIS- under project ID pr001027. … (more)
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 3
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 3
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- 237
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.07.494 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7455.xml