Real-time SPARSE-SENSE cine MR imaging in atrial fibrillation: a feasibility study. (August 2017)
- Record Type:
- Journal Article
- Title:
- Real-time SPARSE-SENSE cine MR imaging in atrial fibrillation: a feasibility study. (August 2017)
- Main Title:
- Real-time SPARSE-SENSE cine MR imaging in atrial fibrillation: a feasibility study
- Authors:
- Goebel, Juliane
Nensa, Felix
Schemuth, Haemi P
Maderwald, Stefan
Quick, Harald H
Schlosser, Thomas
Nassenstein, Kai - Abstract:
- Background: Cardiac magnetic resonance imaging (MRI) relies on correct ECG-gating, which is hindered in arrhythmia. Purpose: To examine whether a prototype free-breathing real-time cine sequence using SPARSE-SENSE (SPARSE) improves left ventricular quantification in atrial fibrillation. Material and Methods: On a 1.5T MR system left ventricular short-axis stacks were acquired of the SPARSE sequence and of a "reference" steady-state free precession (SSFP) sequence with arrhythmia rejection in 20 patients with atrial fibrillation. Two radiologists independently rated arrhythmia-caused artifact severity in both sequences using a 4-point scale. Coefficients of variation of myocardial signal intensity for both sequences were acquired. Volumetry was performed twice by one reader and once by another reader. Correlation between artifact severity and employed sequence was analyzed by modified Fisher's exact test. Coefficients of variation and volumetric data were compared by paired t-test and intraclass correlation. Results: Median arrhythmia-caused artifact severity was 2 in both readers for SSFP and 0 (reader 1)/1 (reader 2) for SPARSE, being significantly lower in SPARSE ( P < 0.001). Mean coefficient of variance was significantly smaller in SPARSE (0.11 ± 0.04) compared to SSFP (0.22 ± 0.13, P = 0.003), which was interpreted as a hint for fewer artifacts in SPARSE. Only a small difference of 9 ± 15 mL was seen for end-systolic volume ( P = 0.019) between sequences, otherwiseBackground: Cardiac magnetic resonance imaging (MRI) relies on correct ECG-gating, which is hindered in arrhythmia. Purpose: To examine whether a prototype free-breathing real-time cine sequence using SPARSE-SENSE (SPARSE) improves left ventricular quantification in atrial fibrillation. Material and Methods: On a 1.5T MR system left ventricular short-axis stacks were acquired of the SPARSE sequence and of a "reference" steady-state free precession (SSFP) sequence with arrhythmia rejection in 20 patients with atrial fibrillation. Two radiologists independently rated arrhythmia-caused artifact severity in both sequences using a 4-point scale. Coefficients of variation of myocardial signal intensity for both sequences were acquired. Volumetry was performed twice by one reader and once by another reader. Correlation between artifact severity and employed sequence was analyzed by modified Fisher's exact test. Coefficients of variation and volumetric data were compared by paired t-test and intraclass correlation. Results: Median arrhythmia-caused artifact severity was 2 in both readers for SSFP and 0 (reader 1)/1 (reader 2) for SPARSE, being significantly lower in SPARSE ( P < 0.001). Mean coefficient of variance was significantly smaller in SPARSE (0.11 ± 0.04) compared to SSFP (0.22 ± 0.13, P = 0.003), which was interpreted as a hint for fewer artifacts in SPARSE. Only a small difference of 9 ± 15 mL was seen for end-systolic volume ( P = 0.019) between sequences, otherwise no significant difference was detected (end-diastolic volume, P = 0.200; stroke volume, P = 0.554; ejection fraction, P = 0.136; myocardial mass, P = 0.353). Intraclass correlation between sequences was good to excellent (range, 0.80–0.97). Conclusion: Real-time MRI with SPARSE data sampling is promising in atrial fibrillation because it reduces arrhythmia-caused artifacts. … (more)
- Is Part Of:
- Acta radiologica. Volume 58:Number 8(2017:Aug.)
- Journal:
- Acta radiologica
- Issue:
- Volume 58:Number 8(2017:Aug.)
- Issue Display:
- Volume 58, Issue 8 (2017)
- Year:
- 2017
- Volume:
- 58
- Issue:
- 8
- Issue Sort Value:
- 2017-0058-0008-0000
- Page Start:
- 922
- Page End:
- 928
- Publication Date:
- 2017-08
- Subjects:
- Real-time imaging -- SPARSE-SENSE cine imaging -- SPARSE sampling -- left ventricular volumetry -- absolute arrhythmia
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185116681037 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7691.xml