Study of personal dosimetry efficiency in procedures of abdominal aortic aneurism in interventional radiology. (September 2016)
- Record Type:
- Journal Article
- Title:
- Study of personal dosimetry efficiency in procedures of abdominal aortic aneurism in interventional radiology. (September 2016)
- Main Title:
- Study of personal dosimetry efficiency in procedures of abdominal aortic aneurism in interventional radiology
- Authors:
- Bacchim Neto, Fernando A.
Alves, Allan F.F.
Rosa, Maria E.D.
de Oliveira, Marcela
de Freitas, Carlos C.M.
Moura, Regina
Pina, Diana R. - Abstract:
- Abstract : Introduction: Interventional Radiology provides unquestionable benefits and replaces extremely invasive and difficult recovery procedures for the patient; however, excessive exposure to radiation can cause severe damage to patients and requires health care for professionals. The assessment of doses received under typical conditions procedures in routine sectors are essential. Thermoluminescent dosimeters are the most widely used radiation dosimeters due to its measurement accuracy and good proportionality response in the diagnostic energy range. Purpose: The objective of this paper is to evaluate the currently dosimetry technique employed in medical staff during interventional radiology procedures. Materials and methods: In each evaluated procedures, dosimeters were fixed at the following locations: a few inches below the eye lens (on top of the surgical mask), thyroid, chest, gonads, hand (bottom of the pulse) and foot, above the radiological protection vests as lead apron and thyroid shield. Equivalent doses rate profiles were estimated based on TLD readings related to the duration of each procedure. Results: The equivalent dose rate profile shows a tendency of difference between dose rate found in the chest in relation to the abdomen, hands and feet. Statistically, dose rates found in the hands differ from those found in the chest with p = 0.05. Conclusion: These results suggest that only a dosimeter placed on the chest does not describe faithfully theAbstract : Introduction: Interventional Radiology provides unquestionable benefits and replaces extremely invasive and difficult recovery procedures for the patient; however, excessive exposure to radiation can cause severe damage to patients and requires health care for professionals. The assessment of doses received under typical conditions procedures in routine sectors are essential. Thermoluminescent dosimeters are the most widely used radiation dosimeters due to its measurement accuracy and good proportionality response in the diagnostic energy range. Purpose: The objective of this paper is to evaluate the currently dosimetry technique employed in medical staff during interventional radiology procedures. Materials and methods: In each evaluated procedures, dosimeters were fixed at the following locations: a few inches below the eye lens (on top of the surgical mask), thyroid, chest, gonads, hand (bottom of the pulse) and foot, above the radiological protection vests as lead apron and thyroid shield. Equivalent doses rate profiles were estimated based on TLD readings related to the duration of each procedure. Results: The equivalent dose rate profile shows a tendency of difference between dose rate found in the chest in relation to the abdomen, hands and feet. Statistically, dose rates found in the hands differ from those found in the chest with p = 0.05. Conclusion: These results suggest that only a dosimeter placed on the chest does not describe faithfully the radiation doses in these professionals. Two dosimeters placed at the height of the abdomen of professionals, one inside the lead protections and other outside, may indicate more accurately the effective dose. Disclosure: The authors declare that there is no conflict of interest. … (more)
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 3
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 3
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- 336
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.07.252 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7454.xml