Evaluation of a small field of view SiPM array detector based on a LGSO:Ce pixellated scintillator. (September 2016)
- Record Type:
- Journal Article
- Title:
- Evaluation of a small field of view SiPM array detector based on a LGSO:Ce pixellated scintillator. (September 2016)
- Main Title:
- Evaluation of a small field of view SiPM array detector based on a LGSO:Ce pixellated scintillator
- Authors:
- David, S.
Fysikopoulos, E.
Kalyvas, N. - Abstract:
- Abstract : Introduction: Silicon photomultiplier arrays can be used in dedicated small field of view animal imaging detectors and especially in those used to head PET/MR studies in mice due to their small size and flexibility. Ce doped LGSO scintillator crystal is based on a mixture of LSO and GSO orthosilicates (Lu2x-_ Gd2-2x_ SiO5 :Ce – LGSO:Ce) and has attracted researcher's attention because of high density of 7 g/cm 3, high light output (∼32000 ph/MeV) and fast scintillation decay time (∼40 ns). Purpose: The purpose of this study is to investigate the behavior of the ArraySL-4 (4 × 4 element array of 3 × 3 mm 2 silicon photomultipliers) optical detector coupled to a 6 × 6 LGSO:Ce scintillator array, with 1.9 × 1.9 × 5 mm 3 crystal size elements, for possible applications in small field of view PET imaging detectors. Evaluation was carried out with 137 Cs radioactive source and results regarding energy resolution and peak to valley ratio are presented. Materials and methods: We have developed a symmetric resistive charge division circuit to read out the signal outputs of 4 × 4 pixel SiPM array reducing the 16 pixel outputs to 4 position signals. The 4 position signals were acquired using a free running sampling technique. An FPGA (Spartan 6 LX150T) was used for triggering and signal processing of the pulses acquired using free running Analog to Digital Converters. Results and conclusion: Evaluation shows a clear visualization of all discrete scintillator elements. TheAbstract : Introduction: Silicon photomultiplier arrays can be used in dedicated small field of view animal imaging detectors and especially in those used to head PET/MR studies in mice due to their small size and flexibility. Ce doped LGSO scintillator crystal is based on a mixture of LSO and GSO orthosilicates (Lu2x-_ Gd2-2x_ SiO5 :Ce – LGSO:Ce) and has attracted researcher's attention because of high density of 7 g/cm 3, high light output (∼32000 ph/MeV) and fast scintillation decay time (∼40 ns). Purpose: The purpose of this study is to investigate the behavior of the ArraySL-4 (4 × 4 element array of 3 × 3 mm 2 silicon photomultipliers) optical detector coupled to a 6 × 6 LGSO:Ce scintillator array, with 1.9 × 1.9 × 5 mm 3 crystal size elements, for possible applications in small field of view PET imaging detectors. Evaluation was carried out with 137 Cs radioactive source and results regarding energy resolution and peak to valley ratio are presented. Materials and methods: We have developed a symmetric resistive charge division circuit to read out the signal outputs of 4 × 4 pixel SiPM array reducing the 16 pixel outputs to 4 position signals. The 4 position signals were acquired using a free running sampling technique. An FPGA (Spartan 6 LX150T) was used for triggering and signal processing of the pulses acquired using free running Analog to Digital Converters. Results and conclusion: Evaluation shows a clear visualization of all discrete scintillator elements. The mean peak to valley ratio of the profiles on the image was measured equal to 13 while the mean energy resolution was measured equal to 18%. … (more)
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 3
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 3
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- 312
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.07.181 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7453.xml