Relative dosimetry in small fields: Which detector to choose?. (September 2016)
- Record Type:
- Journal Article
- Title:
- Relative dosimetry in small fields: Which detector to choose?. (September 2016)
- Main Title:
- Relative dosimetry in small fields: Which detector to choose?
- Authors:
- Dufreneix, S.
Josset, S.
Bartolo, C. Di
Autret, D. - Abstract:
- Abstract : Introduction: Small field dosimetry is a challenging area. Since no ideal detector exists, it is recommended that at least three different suitable types be used. However, only one set of measurement is used by the treatment planning system. Purpose: To compare several detectors and select the adequate one. Materials and methods: Profiles, percent-depth-dose and output factors were conducted on a Novalis TrueBeam STx in MLC shaped beams with a field size of 3, 2, 1 and 0.5 cm for three energies (6 MV, 6 MV FFF and 16 MV) as well as in circular cones of 15–4 mm diameter at 6 MV and 6 MV FFF. Depending on the configuration, various detectors were chosen between the Razor diode (IBA), the 60017 diamond (PTW), the CC01 ion chamber (IBA), the SFD diode (IBA) and EBT3 films. For circular cones, a comparison with the C-serie Novalis of another center was conducted. Results: By analyzing the measurements, the following results were high lightened: due to its large sensitive volume (2.2 mm), the diamond was found inadequate for fields smaller than 6 mm diameter. Both diodes were found in agreement but showed some discrepancies with the film due to their high Z material which virtually sharpens the penubra. The deviations observed between the two Novalis were attributed to the different positions of the jaws. Conclusion: In order to keep a unique detector for all small fields measurements, the Razor diode was selected for all energies. Disclosure: No disclosure.
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 3
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 3
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- 312
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.07.180 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7453.xml