Temporal characteristic of the scanner influencing dosimetry using radiochromic film. (September 2016)
- Record Type:
- Journal Article
- Title:
- Temporal characteristic of the scanner influencing dosimetry using radiochromic film. (September 2016)
- Main Title:
- Temporal characteristic of the scanner influencing dosimetry using radiochromic film
- Authors:
- Gotanda, T.
Katsuda, T.
Gotanda, R.
Akagawa, T.
Tanki, N.
Kuwano, T.
Kawaji, Y.
Shimono, T.
Fukuda, K.
Mizumoto, T. - Abstract:
- Abstract : Introduction: Recently developed radiochromic films can easily measure the absorbed doses by using a flat-bed scanner. However, in a GAFCHROMIC EBT3 (EBT3) radiochromic film, the precision of the measurement was compromised because of the change in density caused by the scan timing of image acquisition using a flat-bed scanner. Purpose: The purpose of this study was to investigate the temporal light source change of a flat-bed scanner affecting the density of EBT3. Materials and methods: EBT3 without irradiation was used to remove non-uniformity error caused by irradiation. EBT3 was scanned every hour (0–6 h) from power activation to investigate the temporal light source change of a flat-bed scanner (EPSON ES-10000G). In addition, five consecutive scans were performed every hour. Scan parameters were RGB (48 bit) mode, 100 dpi, the reflection mode. Image data of EBT3 was divided into R, G, and B modes, and the R (16 bit) mode was used. The region of interest has a diameter of 75 pixels in the center of the EBT3 sheet. Results: The density gradually decreases after power activation and became the plateau 5 h later. After the first scan, a low density is observed: the density was stable after the third scan. Conclusion: To improve repeatability of EBT3, the scan must be performed only after 5 h power activation. In addition, the image data obtained after the third consecutive scan must be used. Disclosure: We have no disclosure and financial support.
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 3
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 3
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- 308
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.07.170 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7453.xml