Comparison between intensity modulation techniques in the prostate cancer treatment. (September 2016)
- Record Type:
- Journal Article
- Title:
- Comparison between intensity modulation techniques in the prostate cancer treatment. (September 2016)
- Main Title:
- Comparison between intensity modulation techniques in the prostate cancer treatment
- Authors:
- Fondelli, S.
Russo, S.
Peruzzi, I.
Barca, R.
Esposito, M.
Leonulli, B. Grilli
Paoletti, L.
Rossi, F.
Alpi, P.
Ghirelli, A.
Pini, S.
Bastiani, P. - Abstract:
- Abstract : Introduction: Comparison between VMAT and IMRT, in terms of plan quality is great topic discussion in literature. Purpose: Aim of this work is to assess VMAT dosimetric results compared to IMRT ones on prostate site. Materials and methods: A comparison was made between IMRT and VMAT plans on the first 30 consecutive patients treated with VMAT moderately hypofractionated radiotherapy: 70.2 Gy/26 fractions of 2.7 Gy. IMRT and VMAT plans were elaborated by TPS Elekta Monaco® using a rabiobiological optimization approach. Plans were compared by evaluating D105%, D95%, D93%, D90%, Dmean and D0.5% for the PTV coverage, while for Organs at Risk (OARs), in addition to Dmean and D0.5%, the % of organ receiving 57, 61, 65.8 and 68.4 Gy (rectum), 57, 61, 65.8 and 68.4 (bladder), 35, 39.5 and 43.9 Gy (femoral heads) were considered of interest. Results: Dosimetric analysis shows that PTV coverage is better with VMAT technique and that PTV Dmean is higher than about 1 Gy in VMAT treatments: median value for the PTV Dmean was 70, 6 Gy in VMAT technique vs 69, 7 Gy in IMRT. Regarding OARs sparing, VMAT technique offers a higher sparing of bladder (of about 5% of volume at 57, 61 and 65 Gy) and femoral heads (of about 15% of volume at 30 Gy). Conclusions: Respect to IMRT, VMAT offers higher plan quality with a better PTV coverage. Regarding OARs, VMAT offers higher sparing of bladder and femoral heads. Besides, VMAT is able to provide a considerable reduction in treatment timeAbstract : Introduction: Comparison between VMAT and IMRT, in terms of plan quality is great topic discussion in literature. Purpose: Aim of this work is to assess VMAT dosimetric results compared to IMRT ones on prostate site. Materials and methods: A comparison was made between IMRT and VMAT plans on the first 30 consecutive patients treated with VMAT moderately hypofractionated radiotherapy: 70.2 Gy/26 fractions of 2.7 Gy. IMRT and VMAT plans were elaborated by TPS Elekta Monaco® using a rabiobiological optimization approach. Plans were compared by evaluating D105%, D95%, D93%, D90%, Dmean and D0.5% for the PTV coverage, while for Organs at Risk (OARs), in addition to Dmean and D0.5%, the % of organ receiving 57, 61, 65.8 and 68.4 Gy (rectum), 57, 61, 65.8 and 68.4 (bladder), 35, 39.5 and 43.9 Gy (femoral heads) were considered of interest. Results: Dosimetric analysis shows that PTV coverage is better with VMAT technique and that PTV Dmean is higher than about 1 Gy in VMAT treatments: median value for the PTV Dmean was 70, 6 Gy in VMAT technique vs 69, 7 Gy in IMRT. Regarding OARs sparing, VMAT technique offers a higher sparing of bladder (of about 5% of volume at 57, 61 and 65 Gy) and femoral heads (of about 15% of volume at 30 Gy). Conclusions: Respect to IMRT, VMAT offers higher plan quality with a better PTV coverage. Regarding OARs, VMAT offers higher sparing of bladder and femoral heads. Besides, VMAT is able to provide a considerable reduction in treatment time offering a better delivery efficiency. … (more)
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 3
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 3
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- 311
- Page End:
- 312
- Publication Date:
- 2016-09
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.07.179 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7452.xml