Optimum wavelength of ultraviolet rays in gafchromic EBT2. (September 2016)
- Record Type:
- Journal Article
- Title:
- Optimum wavelength of ultraviolet rays in gafchromic EBT2. (September 2016)
- Main Title:
- Optimum wavelength of ultraviolet rays in gafchromic EBT2
- Authors:
- Katsuda, T.
Gotanda, R.
Gotanda, T.
Akagawa, T.
Tanki, N.
Kuwano, T.
Noguchi, A.
Yabunaka, K. - Abstract:
- Abstract : Introduction: Gafchromic films have been used for the measurement of X-ray dose in diagnostic radiology. UV-A ray can be used as a substitute for X-rays in the double exposure technique to compensate for nonuniformity error of Gafchromic EBT2. Purpose: When using a UV-A light emitting diode (UV-A LED), it is necessary to determine the optimal UV-A wavelength to react with the active layer of Gafchromic EBT2. Therefore, changes in the optical density of Gafchromic EBT2 induced by UV-A were investigated by irradiating it at various wavelengths with UV-A LED. Materials and methods: At first, Gafchromic EBT2 was pre-irradiated using a uniform UV-A by using fluorescent lamp for 60 min from a distance of 72 cm to reduce nonuniformity error. Second, Gafchromic EBT2 was irradiated for 60 min from a distance of 5.3 cm using a UV-A LED at a wavelength of 353–410 nm. The maximum, minimum, and mean ± standard deviation of pixel values of the subtraction images were evaluated using 0.5 inch of circular region of interest (ROI). The most sensitive wavelength of UV ray was decided. In addition, UV strength was measured in each UV-A LED. Results: When a UV-A LED wavelength of 375 nm was used, the mean ± SD of pixel value of Gafchromic EBT2 was indicated highly pixel value. It was 8915.25 ± 608.86. A 375 nm wavelength UV-A was most effective and sensitive for Gafchromic EBT2. Conclusion: The 375 nm wavelength of UV-A is available as a substitute for X-rays in the double exposureAbstract : Introduction: Gafchromic films have been used for the measurement of X-ray dose in diagnostic radiology. UV-A ray can be used as a substitute for X-rays in the double exposure technique to compensate for nonuniformity error of Gafchromic EBT2. Purpose: When using a UV-A light emitting diode (UV-A LED), it is necessary to determine the optimal UV-A wavelength to react with the active layer of Gafchromic EBT2. Therefore, changes in the optical density of Gafchromic EBT2 induced by UV-A were investigated by irradiating it at various wavelengths with UV-A LED. Materials and methods: At first, Gafchromic EBT2 was pre-irradiated using a uniform UV-A by using fluorescent lamp for 60 min from a distance of 72 cm to reduce nonuniformity error. Second, Gafchromic EBT2 was irradiated for 60 min from a distance of 5.3 cm using a UV-A LED at a wavelength of 353–410 nm. The maximum, minimum, and mean ± standard deviation of pixel values of the subtraction images were evaluated using 0.5 inch of circular region of interest (ROI). The most sensitive wavelength of UV ray was decided. In addition, UV strength was measured in each UV-A LED. Results: When a UV-A LED wavelength of 375 nm was used, the mean ± SD of pixel value of Gafchromic EBT2 was indicated highly pixel value. It was 8915.25 ± 608.86. A 375 nm wavelength UV-A was most effective and sensitive for Gafchromic EBT2. Conclusion: The 375 nm wavelength of UV-A is available as a substitute for X-rays in the double exposure technique. Disclosure: Research supported byJSPS KAKENHI Grant Number26460740 . … (more)
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 3
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 3
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- 286
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.07.102 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7452.xml