Ultraviolet ray wavelength in Gafchromic XR-RV3 and XR-SP2 films. (September 2016)
- Record Type:
- Journal Article
- Title:
- Ultraviolet ray wavelength in Gafchromic XR-RV3 and XR-SP2 films. (September 2016)
- Main Title:
- Ultraviolet ray wavelength in Gafchromic XR-RV3 and XR-SP2 films
- Authors:
- Kuwano, T.
Takeda, Y.
Katsuda, T.
Gotanda, R.
Gotanda, T.
Akagawa, T.
Tanki, N.
Noguchi, A.
Yabunaka, K. - Abstract:
- Abstract : Introduction: Gafchromic films have been used for the measurement of X-ray dose in diagnostic radiology. Correlation between color density change and ultraviolet (UV) wavelength of Gafchromic XR-RV3 and XR-SP2 were studied. UV irradiation is considered as an X-ray substitute in the double exposure technique. It is one of the correction methods for the nonuniformity error of Gafchromic XR-RV3 and XR-SP2. Purpose: It is to determine the UV suitable wavelength of a UV light emitting diode (UV LED) that is used as a substitute for X-rays in the double exposure technique for the Gafchromic XR-RV3 and XR-SP2. Materials and methods: UV LED that UV rays at a wavelength of 353 nm and 5-nm increments from 360 to 400 nm were used. Gafchromic XR-RV3 or XR-SP2 was irradiated with UV of different wavelengths through the 30 mm diameter of irradiation hole for 2 and 4 h, at a distance of 53 mm, respectively. Gafchromic XR-RV3 or XR-SP2 was fixed onto an acrylic plate of 3 mm thickness for assistance with scan. A circular region of interest (ROI) of 0.5 inch for measurements of pixel value was set in the center of the UV irradiation region. The mean pixel values ± standard deviation (SD) was obtained. Results: Indicated high pixel value of Gafchromic XR-RV3 and XR-SP2 were 1276.81 ± 254.30 (395 nm) and 576.46 ± 219.75 (400 nm), respectively. Conclusions: The irradiation of Gafchromic XR-RV3 and XR-SP2 with homogeneous UV rays by the UV-LED wavelengths of 395 or 400 nm can correctAbstract : Introduction: Gafchromic films have been used for the measurement of X-ray dose in diagnostic radiology. Correlation between color density change and ultraviolet (UV) wavelength of Gafchromic XR-RV3 and XR-SP2 were studied. UV irradiation is considered as an X-ray substitute in the double exposure technique. It is one of the correction methods for the nonuniformity error of Gafchromic XR-RV3 and XR-SP2. Purpose: It is to determine the UV suitable wavelength of a UV light emitting diode (UV LED) that is used as a substitute for X-rays in the double exposure technique for the Gafchromic XR-RV3 and XR-SP2. Materials and methods: UV LED that UV rays at a wavelength of 353 nm and 5-nm increments from 360 to 400 nm were used. Gafchromic XR-RV3 or XR-SP2 was irradiated with UV of different wavelengths through the 30 mm diameter of irradiation hole for 2 and 4 h, at a distance of 53 mm, respectively. Gafchromic XR-RV3 or XR-SP2 was fixed onto an acrylic plate of 3 mm thickness for assistance with scan. A circular region of interest (ROI) of 0.5 inch for measurements of pixel value was set in the center of the UV irradiation region. The mean pixel values ± standard deviation (SD) was obtained. Results: Indicated high pixel value of Gafchromic XR-RV3 and XR-SP2 were 1276.81 ± 254.30 (395 nm) and 576.46 ± 219.75 (400 nm), respectively. Conclusions: The irradiation of Gafchromic XR-RV3 and XR-SP2 with homogeneous UV rays by the UV-LED wavelengths of 395 or 400 nm can correct the nonuniformity error of the active layer efficiently. Disclosure: Research supported byJSPS KAKENHI Grant Number26460740 . … (more)
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 3
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 3
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- 288
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.07.109 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7452.xml