X-ray response of a digital detector for dental radiographs. (September 2016)
- Record Type:
- Journal Article
- Title:
- X-ray response of a digital detector for dental radiographs. (September 2016)
- Main Title:
- X-ray response of a digital detector for dental radiographs
- Authors:
- Kalyvas, N.
Maragkaki, P.
Bakas, A.
Fountos, G.
Koukou, V.
Martini, N.
Michail, C.
Valais, I.
Kandarakis, I. - Abstract:
- Abstract : Introduction: Current dental imaging technology offers indirect detectors capable of digital imaging. These detectors incorporate a scintillator coupled to a photoreceptor. Purpose: The purpose of this work is to study the X-ray response of a commercially available SCHICK CDR CMOS detector for dental radiography, in terms of detector response (mean pixel value and standard deviation) per incident air-kerma and the spatial resolution. Materials and methods: The detector was uniformly exposed at a Del Medical Eureka X-ray radiographic system at high voltages of 60 kV and 70 kV. The range of the incident air-kerma, measured with the RTI PIRANHA X-ray multimeter, was varying between 0.047 mGy and 0.225 mGy. The mean pixel value and the standard deviation of the derived DICOM images were measured with RadiAnt (Medixant) available software. Spatial resolution was optically estimated by visualizing the image of an irradiating Type1-83 bar pattern. All images were evaluated in 'for presentation' format, in 8 bit format. Results: The detector shows linear response up to 0.170 mGy for 60 kV and up to 0.145 mGy for 70 kVp. For higher air-kerma, mean pixel values tend to saturated at 255 grey level value. The saturation was faster at 70 kV. The coefficient of variation, as well as the standard deviation was found to reduce with respect to incident air-kerma for both X-ray tube voltages. Spatial resolution was observed approximately 10 lp/mm at 60 kVp and 9 lp/mm at 70 kVp.Abstract : Introduction: Current dental imaging technology offers indirect detectors capable of digital imaging. These detectors incorporate a scintillator coupled to a photoreceptor. Purpose: The purpose of this work is to study the X-ray response of a commercially available SCHICK CDR CMOS detector for dental radiography, in terms of detector response (mean pixel value and standard deviation) per incident air-kerma and the spatial resolution. Materials and methods: The detector was uniformly exposed at a Del Medical Eureka X-ray radiographic system at high voltages of 60 kV and 70 kV. The range of the incident air-kerma, measured with the RTI PIRANHA X-ray multimeter, was varying between 0.047 mGy and 0.225 mGy. The mean pixel value and the standard deviation of the derived DICOM images were measured with RadiAnt (Medixant) available software. Spatial resolution was optically estimated by visualizing the image of an irradiating Type1-83 bar pattern. All images were evaluated in 'for presentation' format, in 8 bit format. Results: The detector shows linear response up to 0.170 mGy for 60 kV and up to 0.145 mGy for 70 kVp. For higher air-kerma, mean pixel values tend to saturated at 255 grey level value. The saturation was faster at 70 kV. The coefficient of variation, as well as the standard deviation was found to reduce with respect to incident air-kerma for both X-ray tube voltages. Spatial resolution was observed approximately 10 lp/mm at 60 kVp and 9 lp/mm at 70 kVp. Conclusion: The observed digital detector was found to have better resolution and dynamic range characteristics at 60 kVp. Disclosure: No disclosure. … (more)
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 3
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 3
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- 286
- Page End:
- 287
- Publication Date:
- 2016-09
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.07.104 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7452.xml