Chandel, Rahul - Abstract:
- Abstract: It is important to understand photovoltaic (PV) module degradation for the design of PV systems. In the present study results of degradation in mono-crystalline-silicon PV generator of a solar water pump after 28 years of outdoor exposure at a western Himalayan location in the Indian state of Himachal Pradesh, are presented. The main objective is to study the impact of PV degradation on solar pump performance, reliability and life-expectancy under field conditions. Main defects observed in PV modules are encapsulant discolouration, delamination, oxidation of front grid fingers and anti-reflective coating, glass breakage and bubbles in back sheet. Hot spots are identified using thermal imaging and degradation is quantified by measuring PV parameters under indoor and outdoor conditions. Sun simulator is used to test degraded modules under standard testing conditions. Average power degradation of PV generator is found to increase 1.4% per year which is reasonable considering materials and technology used about three decades ago. The open circuit voltage is found to show an average increase of 2.8% requiring further experimental investigations. The study has relevance in improving the performance and life-expectancy of PV based systems beyond the warranty period of 25 years by replacing most degraded modules. Follow up research areas are also identified. Highlights: Mono-c-Si PV generator degradation of a solar water pump after 28 years of outdoor exposure is studied.Abstract: It is important to understand photovoltaic (PV) module degradation for the design of PV systems. In the present study results of degradation in mono-crystalline-silicon PV generator of a solar water pump after 28 years of outdoor exposure at a western Himalayan location in the Indian state of Himachal Pradesh, are presented. The main objective is to study the impact of PV degradation on solar pump performance, reliability and life-expectancy under field conditions. Main defects observed in PV modules are encapsulant discolouration, delamination, oxidation of front grid fingers and anti-reflective coating, glass breakage and bubbles in back sheet. Hot spots are identified using thermal imaging and degradation is quantified by measuring PV parameters under indoor and outdoor conditions. Sun simulator is used to test degraded modules under standard testing conditions. Average power degradation of PV generator is found to increase 1.4% per year which is reasonable considering materials and technology used about three decades ago. The open circuit voltage is found to show an average increase of 2.8% requiring further experimental investigations. The study has relevance in improving the performance and life-expectancy of PV based systems beyond the warranty period of 25 years by replacing most degraded modules. Follow up research areas are also identified. Highlights: Mono-c-Si PV generator degradation of a solar water pump after 28 years of outdoor exposure is studied. Average power degradation in PV modules is found to increase 1.4% per year. Open circuit voltage is found to show an average increase of 2.8% which requires further research. Study has relevance in improving the performance and life-expectancy of PV systems beyond warranty period. … (more)
- Is Part Of:
- Renewable energy. Volume 78(2015)
- Journal:
- Renewable energy
- Issue:
- Volume 78(2015)
- Issue Display:
- Volume 78, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 78
- Issue:
- 2015
- Issue Sort Value:
- 2015-0078-2015-0000
- Page Start:
- 193
- Page End:
- 202
- Publication Date:
- 2015-06
- Subjects:
- Solar photovoltaic water pump -- PV degradation -- Mono-crystalline silicon solar cells -- Thermal imaging -- Western Himalayas
Renewable energy sources -- Periodicals
Power resources -- Periodicals
Énergies renouvelables -- Périodiques
Ressources énergétiques -- Périodiques
333.794 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09601481 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/renewable-energy/ ↗ - DOI:
- 10.1016/j.renene.2015.01.015 ↗
- Languages:
- English
- ISSNs:
- 0960-1481
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7364.187000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7456.xml