Fast laboratory-based micro-computed tomography for pore-scale research: Illustrative experiments and perspectives on the future. (September 2016)
- Record Type:
- Journal Article
- Title:
- Fast laboratory-based micro-computed tomography for pore-scale research: Illustrative experiments and perspectives on the future. (September 2016)
- Main Title:
- Fast laboratory-based micro-computed tomography for pore-scale research: Illustrative experiments and perspectives on the future
- Authors:
- Bultreys, Tom
Boone, Marijn A.
Boone, Matthieu N.
De Schryver, Thomas
Masschaele, Bert
Van Hoorebeke, Luc
Cnudde, Veerle - Abstract:
- Highlights: State of the art in fast laboratory-based X-ray micro-computed tomography is outlined. Real-time, pore-scale visualization of drainage in Bentheimer with lab-based scanner. Solute transport is imaged at the pore scale in a limestone at 12 s per scan. Abstract: Over the past decade, the wide-spread implementation of laboratory-based X-ray micro-computed tomography (micro-CT) scanners has revolutionized both the experimental and numerical research on pore-scale transport in geological materials. The availability of these scanners has opened up the possibility to image a rock's pore space in 3D almost routinely to many researchers. While challenges do persist in this field, we treat the next frontier in laboratory-based micro-CT scanning: in-situ, time-resolved imaging of dynamic processes. Extremely fast (even sub-second) micro-CT imaging has become possible at synchrotron facilities over the last few years, however, the restricted accessibility of synchrotrons limits the amount of experiments which can be performed. The much smaller X-ray flux in laboratory-based systems bounds the time resolution which can be attained at these facilities. Nevertheless, progress is being made to improve the quality of measurements performed on the sub-minute time scale. We illustrate this by presenting cutting-edge pore scale experiments visualizing two-phase flow and solute transport in real-time with a lab-based environmental micro-CT set-up. To outline the current state of thisHighlights: State of the art in fast laboratory-based X-ray micro-computed tomography is outlined. Real-time, pore-scale visualization of drainage in Bentheimer with lab-based scanner. Solute transport is imaged at the pore scale in a limestone at 12 s per scan. Abstract: Over the past decade, the wide-spread implementation of laboratory-based X-ray micro-computed tomography (micro-CT) scanners has revolutionized both the experimental and numerical research on pore-scale transport in geological materials. The availability of these scanners has opened up the possibility to image a rock's pore space in 3D almost routinely to many researchers. While challenges do persist in this field, we treat the next frontier in laboratory-based micro-CT scanning: in-situ, time-resolved imaging of dynamic processes. Extremely fast (even sub-second) micro-CT imaging has become possible at synchrotron facilities over the last few years, however, the restricted accessibility of synchrotrons limits the amount of experiments which can be performed. The much smaller X-ray flux in laboratory-based systems bounds the time resolution which can be attained at these facilities. Nevertheless, progress is being made to improve the quality of measurements performed on the sub-minute time scale. We illustrate this by presenting cutting-edge pore scale experiments visualizing two-phase flow and solute transport in real-time with a lab-based environmental micro-CT set-up. To outline the current state of this young field and its relevance to pore-scale transport research, we critically examine its current bottlenecks and their possible solutions, both on the hardware and the software level. Further developments in laboratory-based, time-resolved imaging could prove greatly beneficial to our understanding of transport behavior in geological materials and to the improvement of pore-scale modeling by providing valuable validation. … (more)
- Is Part Of:
- Advances in water resources. Volume 95(2016)
- Journal:
- Advances in water resources
- Issue:
- Volume 95(2016)
- Issue Display:
- Volume 95, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 95
- Issue:
- 2016
- Issue Sort Value:
- 2016-0095-2016-0000
- Page Start:
- 341
- Page End:
- 351
- Publication Date:
- 2016-09
- Subjects:
- 4D micro-computed tomography -- Dynamic imaging -- Pore scale -- Drainage -- Solute transport
Hydrology -- Periodicals
Hydrodynamics -- Periodicals
Hydraulic engineering -- Periodicals
551.48 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03091708 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.advwatres.2015.05.012 ↗
- Languages:
- English
- ISSNs:
- 0309-1708
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0712.120000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: