Direction modulated brachytherapy (DMBT) tandem applicator for cervical cancer treatment: Choosing the optimal shielding material. Issue 8 (21st June 2018)
- Record Type:
- Journal Article
- Title:
- Direction modulated brachytherapy (DMBT) tandem applicator for cervical cancer treatment: Choosing the optimal shielding material. Issue 8 (21st June 2018)
- Main Title:
- Direction modulated brachytherapy (DMBT) tandem applicator for cervical cancer treatment: Choosing the optimal shielding material
- Authors:
- Safigholi, Habib
Han, Dae Yup
Soliman, Abraam
Song, William Y. - Abstract:
- Abstract : Purpose: To investigate the dose modulation capability of a novel MRI‐compatible direction modulated brachytherapy (DMBT) tandem applicator design with various high‐density shielding materials for brachytherapy treatment of cervical cancer. The shield materials that have been evaluated are tantalum (Ta), pure tungsten (W), gold (Au), rhenium (Re), osmium (Os), platinum (Pt), iridium (Ir), and W′ tungsten alloy (95%W, 3.5%Ni, 1.5%Cu). Materials and methods: The recently proposed six‐channel DMBT tandem is composed of nonmagnetic tungsten alloy (W′) rod with diameter of 5.4 mm and coated with 0.3‐mm thick bio‐safe plastic sheath. The tandem shielding material can, however, be individually replaced with various other shields to create directional radiation. Monte Carlo N‐Particle (MCNP) code was used to calculate the three‐dimensional (3D) dose distributions in a water phantom for an HDR 192 Ir (mHDR‐v2) source inside each DMBT tandem with various shields and a plastic conventional tandem (Con.T). Then, the 3D dose distributions were imported into an in‐house‐coded inverse planning optimization algorithm to obtain optimal plans for 12 clinical cases chosen at random from the international RetroEMBRACE dataset involving conventional tandem and ring (Con.T&R) applicators. All plans generated by the DMBT tandem and ring (DMBT&R) with the tungsten alloy [DMBT(W′)&R] were compared with the corresponding Con.T&R plans, to generate benchmark results. These benchmark resultsAbstract : Purpose: To investigate the dose modulation capability of a novel MRI‐compatible direction modulated brachytherapy (DMBT) tandem applicator design with various high‐density shielding materials for brachytherapy treatment of cervical cancer. The shield materials that have been evaluated are tantalum (Ta), pure tungsten (W), gold (Au), rhenium (Re), osmium (Os), platinum (Pt), iridium (Ir), and W′ tungsten alloy (95%W, 3.5%Ni, 1.5%Cu). Materials and methods: The recently proposed six‐channel DMBT tandem is composed of nonmagnetic tungsten alloy (W′) rod with diameter of 5.4 mm and coated with 0.3‐mm thick bio‐safe plastic sheath. The tandem shielding material can, however, be individually replaced with various other shields to create directional radiation. Monte Carlo N‐Particle (MCNP) code was used to calculate the three‐dimensional (3D) dose distributions in a water phantom for an HDR 192 Ir (mHDR‐v2) source inside each DMBT tandem with various shields and a plastic conventional tandem (Con.T). Then, the 3D dose distributions were imported into an in‐house‐coded inverse planning optimization algorithm to obtain optimal plans for 12 clinical cases chosen at random from the international RetroEMBRACE dataset involving conventional tandem and ring (Con.T&R) applicators. All plans generated by the DMBT tandem and ring (DMBT&R) with the tungsten alloy [DMBT(W′)&R] were compared with the corresponding Con.T&R plans, to generate benchmark results. These benchmark results were then considered as reference plans for other shields performances. Plans were normalized to receive the same high‐risk clinical target volume (CTVHR ) D 90 . The D 100, D 10, and V 100 for CTVHR, and D 2cm3 for organs at risk (OARs) of bladder, sigmoid, and rectum were calculated and compared. Results: Transmission factor (TF), that is, the dose in the backside of the DMBT shield over that in the front opening, at a 5 cm distance, were 36.6%, 34.8%, 31.9%, 28.9%, 27.9%, 26.2%, 26.2%, and 25.5%, for Ta, W′, W, Re, Au, Os, Pt, and Ir shields, respectively. On average, the CTVHR values for D 100, V 100, D 10 were not significantly different across all DMBT&R shields and the Con.T&R plans ( P > 0.219). For the D 2cm3, the benchmark results showed significant reductions ( P < 0.03), that is, on average, −8.3% for bladder, −10.7% for rectum, and −10.1% for sigmoid, compared to the Con.T&R plans. However, the various shields showed little improvement from the tungsten alloy (W′), where on average, rectum (bladder) [sigmoid] D 2cm3 were reduced by −1.32% (−0.85%) [−1.01%], −1.25% (−0.78%) [−0.91%], −1.22% (−0.75%) [−0.86%], −0.94% (−0.60%) [−0.70%], −0.84% (−0.51%) [−0.59%], and −0.38% (−0.24%) [−0.23%] for Ir, Pt, Os, Au, Re, and W shields, relative to the benchmark W′ DMBT plans, respectively. These corresponding values for Ta increased by +0.28% (+0.08%) [+0.25%], respectively. Conclusion: The Ir, Pt, Os, Au, Re, and W shielding materials, respectively, in descending order, lead to better OAR sparing than the DMBT(W′)&R plans. However, the amount of improvement is limited and clinically insignificant. This finding suggests that the initial W′ shield remains a suitable choice given the proven MR compatibility, for use in MR‐guided adaptive brachytherapy of cervical cancer. … (more)
- Is Part Of:
- Medical physics. Volume 45:Issue 8(2018)
- Journal:
- Medical physics
- Issue:
- Volume 45:Issue 8(2018)
- Issue Display:
- Volume 45, Issue 8 (2018)
- Year:
- 2018
- Volume:
- 45
- Issue:
- 8
- Issue Sort Value:
- 2018-0045-0008-0000
- Page Start:
- 3524
- Page End:
- 3533
- Publication Date:
- 2018-06-21
- Subjects:
- cervical cancer -- direction modulated brachytherapy -- image‐guided brachytherapy -- optimal shielding material -- tandem applicator
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13030 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7433.xml