Acute Type A Aortic Dissection Treated Using a Tubular Stent-Graft in the Ascending Aorta and a Multibranched Stent-Graft in the Aortic Arch. (February 2017)
- Record Type:
- Journal Article
- Title:
- Acute Type A Aortic Dissection Treated Using a Tubular Stent-Graft in the Ascending Aorta and a Multibranched Stent-Graft in the Aortic Arch. (February 2017)
- Main Title:
- Acute Type A Aortic Dissection Treated Using a Tubular Stent-Graft in the Ascending Aorta and a Multibranched Stent-Graft in the Aortic Arch
- Authors:
- Kölbel, Tilo
Detter, Christian
Carpenter, Sebastian W.
Rohlffs, Fiona
von Kodolitsch, Yskert
Wipper, Sabine
Reichenspurner, Herrmann
Debus, E. Sebastian
Tsilimparis, Nikolaos - Abstract:
- Purpose: To describe the combined use of a tubular stent-graft for the ascending aorta and an inner-branched arch stent-graft for patients with acute type A aortic dissection.Technique: The technique to deploy these modular, custom-made stent-grafts is demonstrated in 2 patients with acute DeBakey type I aortic dissections and significant comorbidities precluding open surgery. Both emergent procedures were made possible by the availability of suitable devices manufactured for elective repair in other patients. After preliminary carotid-subclavian bypass, a long Lunderquist guidewire was introduced from the right femoral artery to the left ventricle for delivery of the Zenith Ascend and Zenith Branched Arch Endovascular Grafts under inflow occlusion. Bridging stent-grafts were delivered to the innominate and left common carotid arteries to connect to the 2 inner branches; the left subclavian artery was occluded. Both cases were technically successful and resulted in exclusion of the false lumen in the ascending aorta. The operating and fluoroscopy times did not exceed those of comparable elective procedures. The patients were rapidly extubated shortly after the procedure and without serious immediate complications. One patient survived 11 months with a satisfactory repair; the other succumbed to complications of recurrent pneumonia after 23 days.Conclusion: Endovascular treatment of patients with acute type A aortic dissection using a combination of tubular and branchedPurpose: To describe the combined use of a tubular stent-graft for the ascending aorta and an inner-branched arch stent-graft for patients with acute type A aortic dissection.Technique: The technique to deploy these modular, custom-made stent-grafts is demonstrated in 2 patients with acute DeBakey type I aortic dissections and significant comorbidities precluding open surgery. Both emergent procedures were made possible by the availability of suitable devices manufactured for elective repair in other patients. After preliminary carotid-subclavian bypass, a long Lunderquist guidewire was introduced from the right femoral artery to the left ventricle for delivery of the Zenith Ascend and Zenith Branched Arch Endovascular Grafts under inflow occlusion. Bridging stent-grafts were delivered to the innominate and left common carotid arteries to connect to the 2 inner branches; the left subclavian artery was occluded. Both cases were technically successful and resulted in exclusion of the false lumen in the ascending aorta. The operating and fluoroscopy times did not exceed those of comparable elective procedures. The patients were rapidly extubated shortly after the procedure and without serious immediate complications. One patient survived 11 months with a satisfactory repair; the other succumbed to complications of recurrent pneumonia after 23 days.Conclusion: Endovascular treatment of patients with acute type A aortic dissection using a combination of tubular and branched stent-grafts in the ascending aorta is feasible and offers an alternative strategy to open surgery. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 24:Number 1(2017:Feb.)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 24:Number 1(2017:Feb.)
- Issue Display:
- Volume 24, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 24
- Issue:
- 1
- Issue Sort Value:
- 2017-0024-0001-0000
- Page Start:
- 75
- Page End:
- 80
- Publication Date:
- 2017-02
- Subjects:
- aortic arch dissection -- aortic arch -- aortic dissection -- ascending aorta -- branched stent-graft -- DeBakey type I aortic dissection -- endograft -- stent-graft -- thoracic aorta dissection -- thoracic aorta -- thoracic endovascular aortic repair -- type A dissection
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1526602816680089 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7397.xml