Use of the Octopus Endograft Technique to Reconstruct Renovisceral Arteries Arising From the False Lumen of a Rapidly Expanding Type B Aortic Dissection After Endovascular Repair. (February 2017)
- Record Type:
- Journal Article
- Title:
- Use of the Octopus Endograft Technique to Reconstruct Renovisceral Arteries Arising From the False Lumen of a Rapidly Expanding Type B Aortic Dissection After Endovascular Repair. (February 2017)
- Main Title:
- Use of the Octopus Endograft Technique to Reconstruct Renovisceral Arteries Arising From the False Lumen of a Rapidly Expanding Type B Aortic Dissection After Endovascular Repair
- Authors:
- Xiong, Jiang
Ge, Yangyang
Liu, Xiaoping
Wang, Lijun
Guo, Wei - Abstract:
- Purpose: To describe the use and 6-month outcomes of the octopus endograft technique to reconstruct renovisceral arteries arising from the false lumen (FL) of a type B aortic dissection after thoracic endovascular aortic repair (TEVAR).Case Report: A 46-year-old man post TEVAR for type B aortic dissection was admitted with persistent back pain and a rapidly expanding residual dissection. The celiac and left renal arteries arose from the FL and the superior mesenteric artery from both lumens, with the FL as its main supply. A 20% oversized Endurant stent-graft was deployed with the short limb just above the beginning of the dissection flap and the long limb in the aortic true lumen. A 120-mm-long Endurant extended limb was delivered antegradely via a conduit and deployed into the FL, with a 3-cm overlap with the short limb of the Endurant main body. The 3 renovisceral arteries were reconstructed by lining each with a series of Viabahn or Fluency stent-grafts whose proximal ends were subsequently placed parallel in the FL Endurant extended limb and dilated with kissing balloons. Imaging at 6 months showed an excluded FL, without stenosis or occlusion in the stent-graft or the renovisceral arteries.Conclusion: This case illustrates the successful use of the octopus endograft technique to reconstruct renovisceral arteries arising from a rapidly expanding FL in a post-TEVAR type B aortic dissection; the technique might be applicable in carefully selected patients.
- Is Part Of:
- Journal of endovascular therapy. Volume 24:Number 1(2017:Feb.)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 24:Number 1(2017:Feb.)
- Issue Display:
- Volume 24, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 24
- Issue:
- 1
- Issue Sort Value:
- 2017-0024-0001-0000
- Page Start:
- 107
- Page End:
- 111
- Publication Date:
- 2017-02
- Subjects:
- endograft -- false lumen -- octopus graft -- parallel grafts -- renovisceral arteries -- stent-graft -- stent-graft–induced new tear -- type B aortic dissection -- thoracoabdominal dissection -- thoracic endovascular aortic repair
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1526602816678993 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7397.xml