High‐efficiency coherence‐preserving harmonic rejection with crystal optics. (14th August 2018)
- Record Type:
- Journal Article
- Title:
- High‐efficiency coherence‐preserving harmonic rejection with crystal optics. (14th August 2018)
- Main Title:
- High‐efficiency coherence‐preserving harmonic rejection with crystal optics
- Authors:
- Zhang, Fan
Allen, Andrew J.
Levine, Lyle E.
Long, Gabrielle G.
Kuzmenko, Ivan
Ilavsky, Jan - Abstract:
- Abstract : A coherence‐preserving harmonic‐rejection scheme based on parallel crystal optics that achieves a total flux ratio of harmonic radiation to fundamental radiation on the order of 10 −10 or lower is reported. Abstract : This work reports a harmonic‐rejection scheme based on the combination of Si(111) monochromator and Si(220) harmonic‐rejection crystal optics. This approach is of importance to a wide range of X‐ray applications in all three major branches of modern X‐ray science (scattering, spectroscopy, imaging) based at major facilities, and especially relevant to the capabilities offered by the new diffraction‐limited storage rings. It was demonstrated both theoretically and experimentally that, when used with a synchrotron undulator source over a broad range of X‐ray energies of interest, the harmonic‐rejection crystals transmit the incident harmonic X‐rays on the order of 10 −6 . Considering the flux ratio of fundamental and harmonic X‐rays in the incident beam, this scheme achieves a total flux ratio of harmonic radiation to fundamental radiation on the order of 10 −10 . The spatial coherence of the undulator beam is preserved in the transmitted fundamental radiation while the harmonic radiation is suppressed, making this scheme suitable not only for current third‐generation synchrotron sources but also for the new diffraction‐limited storage rings where coherence preservation is an even higher priority. Compared with conventional harmonic‐rejection mirrors,Abstract : A coherence‐preserving harmonic‐rejection scheme based on parallel crystal optics that achieves a total flux ratio of harmonic radiation to fundamental radiation on the order of 10 −10 or lower is reported. Abstract : This work reports a harmonic‐rejection scheme based on the combination of Si(111) monochromator and Si(220) harmonic‐rejection crystal optics. This approach is of importance to a wide range of X‐ray applications in all three major branches of modern X‐ray science (scattering, spectroscopy, imaging) based at major facilities, and especially relevant to the capabilities offered by the new diffraction‐limited storage rings. It was demonstrated both theoretically and experimentally that, when used with a synchrotron undulator source over a broad range of X‐ray energies of interest, the harmonic‐rejection crystals transmit the incident harmonic X‐rays on the order of 10 −6 . Considering the flux ratio of fundamental and harmonic X‐rays in the incident beam, this scheme achieves a total flux ratio of harmonic radiation to fundamental radiation on the order of 10 −10 . The spatial coherence of the undulator beam is preserved in the transmitted fundamental radiation while the harmonic radiation is suppressed, making this scheme suitable not only for current third‐generation synchrotron sources but also for the new diffraction‐limited storage rings where coherence preservation is an even higher priority. Compared with conventional harmonic‐rejection mirrors, where coherence is poorly preserved and harmonic rejection is less effective, this scheme has the added advantage of lower cost and footprint. This approach has been successfully utilized at the ultra‐small‐angle X‐ray scattering instrument at the Advanced Photon Source for scattering, imaging and coherent X‐ray photon correlation spectroscopy experiments. With minor modification, the harmonic rejection can be improved by a further five orders of magnitude, enabling even more performance capabilities. … (more)
- Is Part Of:
- Journal of synchrotron radiation. Volume 25:Part 5(2018)
- Journal:
- Journal of synchrotron radiation
- Issue:
- Volume 25:Part 5(2018)
- Issue Display:
- Volume 25, Issue 5, Part 5 (2018)
- Year:
- 2018
- Volume:
- 25
- Issue:
- 5
- Part:
- 5
- Issue Sort Value:
- 2018-0025-0005-0005
- Page Start:
- 1354
- Page End:
- 1361
- Publication Date:
- 2018-08-14
- Subjects:
- harmonic rejection -- monochromator -- coherent X‐ray scattering -- SAXS -- XAFS
Synchrotron radiation -- Periodicals
Free electron lasers -- Periodicals
539.73505 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1107/S16005775 ↗
http://journals.iucr.org/s/journalhomepage.html ↗
http://www.blackwell-synergy.com/openurl?genre=journal&issn=0909-0495 ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1107/S1600577518009645 ↗
- Languages:
- English
- ISSNs:
- 0909-0495
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5068.035000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7415.xml