Validation of the Beneware model ABP-021 ambulatory blood pressure monitor according to the revised 2010 European Society of hypertension international protocol. Issue 4 (August 2018)
- Record Type:
- Journal Article
- Title:
- Validation of the Beneware model ABP-021 ambulatory blood pressure monitor according to the revised 2010 European Society of hypertension international protocol. Issue 4 (August 2018)
- Main Title:
- Validation of the Beneware model ABP-021 ambulatory blood pressure monitor according to the revised 2010 European Society of hypertension international protocol
- Authors:
- Pereira, Telmo
Guimarães, João - Abstract:
- Abstract : Objectives: This study aimed to evaluate the accuracy of the Beneware model ABP-021 oscillometric blood pressure monitor in the general population according to the European Society of Hypertension International Protocol (ESH-IP). The accuracy of the device was assessed in relation to various clinical variables, including age, sex, BMI, and arm circumference. Methods: Thirty-three individuals (18 men and 15 women), with a mean age of 36±14 years (age range: 20–68 years), were studied according to the recommendations of the ESH-IP. Sequential same-arm blood pressure measurements were performed, alternating between a mercury standard and the automatic device. The differences among the test–control measurements were assessed and divided into categorization zones of 5, 10, and 15 mmHg discrepancy. Results: The device complied with the quality requirements of the ESH-IP. The device–observer disagreement was −1.2±4.7 mmHg for systolic blood pressure (SBP) and −1.7±4.3 mmHg for diastolic blood pressure (DBP). The device produced 77, 93, and 98 measurements, respectively, within the 5, 10, and 15 mmHg discrepancy limits for SBP. For DBP, 80, 97, and 99 measurements were observed within the 5, 10, and 15 mmHg discrepancy limits. The number of participants with two or three of the device–observer differences within 5 mmHg was 26 for SBP and 29 for DBP, whereas there were only two participants with no device–observer differences within 5 mmHg for DBP. Conclusion: These dataAbstract : Objectives: This study aimed to evaluate the accuracy of the Beneware model ABP-021 oscillometric blood pressure monitor in the general population according to the European Society of Hypertension International Protocol (ESH-IP). The accuracy of the device was assessed in relation to various clinical variables, including age, sex, BMI, and arm circumference. Methods: Thirty-three individuals (18 men and 15 women), with a mean age of 36±14 years (age range: 20–68 years), were studied according to the recommendations of the ESH-IP. Sequential same-arm blood pressure measurements were performed, alternating between a mercury standard and the automatic device. The differences among the test–control measurements were assessed and divided into categorization zones of 5, 10, and 15 mmHg discrepancy. Results: The device complied with the quality requirements of the ESH-IP. The device–observer disagreement was −1.2±4.7 mmHg for systolic blood pressure (SBP) and −1.7±4.3 mmHg for diastolic blood pressure (DBP). The device produced 77, 93, and 98 measurements, respectively, within the 5, 10, and 15 mmHg discrepancy limits for SBP. For DBP, 80, 97, and 99 measurements were observed within the 5, 10, and 15 mmHg discrepancy limits. The number of participants with two or three of the device–observer differences within 5 mmHg was 26 for SBP and 29 for DBP, whereas there were only two participants with no device–observer differences within 5 mmHg for DBP. Conclusion: These data show that the Beneware model ABP-021 monitor meets the requirements of the ESH-IP, in static conditions, indicating its suitability for measuring blood pressure in the general adult population. … (more)
- Is Part Of:
- Blood pressure monitoring. Volume 23:Issue 4(2018)
- Journal:
- Blood pressure monitoring
- Issue:
- Volume 23:Issue 4(2018)
- Issue Display:
- Volume 23, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 23
- Issue:
- 4
- Issue Sort Value:
- 2018-0023-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-08
- Subjects:
- ambulatory blood pressure monitoring -- arterial hypertension -- blood pressure -- validation
Blood pressure -- Measurement -- Periodicals
Blood Pressure Determination -- Periodicals
Blood Pressure Monitoring, Ambulatory -- Periodicals
Blood Pressure Monitors -- Periodicals
Hypertension -- Periodicals
612.140287 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00126097-000000000-00000&NEWS=N ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00126097-000000000-00000 ↗
http://www.bpmonitoring.com/ ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1097/MBP.0000000000000330 ↗
- Languages:
- English
- ISSNs:
- 1359-5237
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2113.035500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7405.xml