Quantitative assessment of parent vessel and distal intracranial hemodynamics following pipeline flow diversion. Issue 1 (February 2017)
- Record Type:
- Journal Article
- Title:
- Quantitative assessment of parent vessel and distal intracranial hemodynamics following pipeline flow diversion. Issue 1 (February 2017)
- Main Title:
- Quantitative assessment of parent vessel and distal intracranial hemodynamics following pipeline flow diversion
- Authors:
- Shakur, Sophia F
Aletich, Victor A
Amin-Hanjani, Sepideh
Hussein, Ahmed E
Charbel, Fady T
Alaraj, Ali - Abstract:
- Background: Pipeline embolization devices (PEDs) are commonly used for endovascular treatment of cerebral aneurysms but can be associated with delayed ipsilateral intraparenchymal hemorrhage. Although intra-aneurysmal hemodynamic changes have been studied, parent vessel and intracranial hemodynamics after PED use are unknown. We examine the impact of flow diversion on parent artery and distal intracranial hemodynamics. Method: Patients with internal carotid cerebral aneurysms treated with PED who had flow volume rate, flow velocities, pulsatility index, resistance index, Lindegaard ratio, and wall shear stress (WSS) obtained after treatment using quantitative magnetic resonance angiography were reviewed. Means were compared between ipsilateral and contralateral internal carotid artery (ICA) and middle cerebral artery (MCA) using paired t tests. Results: A total of 18 patients were included. Mean flow volume rate was lower in the ipsilateral versus contralateral ICA ( p = 0.04) but tended to be higher in the ipsilateral versus contralateral MCA ( p = 0.08). Lindegaard ratio was higher ipsilateral to the PED in diastole ( p = 0.05). Although there was no significant difference in flow velocities, pulsatility or resistance indices, and WSS, the two cases in our cohort with hemorrhagic complications did display significant changes in MCA flows and MCA WSS. Conclusion: PED placement appears to alter the elasticity of the stented ICA segment, with lower flows in the ipsilateralBackground: Pipeline embolization devices (PEDs) are commonly used for endovascular treatment of cerebral aneurysms but can be associated with delayed ipsilateral intraparenchymal hemorrhage. Although intra-aneurysmal hemodynamic changes have been studied, parent vessel and intracranial hemodynamics after PED use are unknown. We examine the impact of flow diversion on parent artery and distal intracranial hemodynamics. Method: Patients with internal carotid cerebral aneurysms treated with PED who had flow volume rate, flow velocities, pulsatility index, resistance index, Lindegaard ratio, and wall shear stress (WSS) obtained after treatment using quantitative magnetic resonance angiography were reviewed. Means were compared between ipsilateral and contralateral internal carotid artery (ICA) and middle cerebral artery (MCA) using paired t tests. Results: A total of 18 patients were included. Mean flow volume rate was lower in the ipsilateral versus contralateral ICA ( p = 0.04) but tended to be higher in the ipsilateral versus contralateral MCA ( p = 0.08). Lindegaard ratio was higher ipsilateral to the PED in diastole ( p = 0.05). Although there was no significant difference in flow velocities, pulsatility or resistance indices, and WSS, the two cases in our cohort with hemorrhagic complications did display significant changes in MCA flows and MCA WSS. Conclusion: PED placement appears to alter the elasticity of the stented ICA segment, with lower flows in the ipsilateral versus contralateral ICA. Conversely, MCA flows and MCA WSS are higher in the ipsilateral MCA among patients with hemorrhage after PED placement, suggesting the role of disrupted distal hemodynamics in delayed ipsilateral intraparenchymal hemorrhage. … (more)
- Is Part Of:
- Interventional neuroradiology. Volume 23:Issue 1(2017:Feb.)
- Journal:
- Interventional neuroradiology
- Issue:
- Volume 23:Issue 1(2017:Feb.)
- Issue Display:
- Volume 23, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 23
- Issue:
- 1
- Issue Sort Value:
- 2017-0023-0001-0000
- Page Start:
- 34
- Page End:
- 40
- Publication Date:
- 2017-02
- Subjects:
- Cerebral aneurysm -- flow diversion -- intracranial hemodynamics -- magnetic resonance angiography -- pipeline embolization device
Nervous system -- Interventional radiology -- Periodicals
Nervous system -- Radiography -- Periodicals
Nervous System Diseases -- Periodicals -- radiography
Neuroradiography -- Periodicals
Radiography, Interventional -- Periodicals
Nervous system -- Radiography
Periodicals
617.4805 - Journal URLs:
- http://ine.sagepub.com/ ↗
http://web.ebscohost.com ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1673/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1591019916668842 ↗
- Languages:
- English
- ISSNs:
- 1591-0199
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7401.xml