Risk of Appropriate Therapy and Death Before Therapy After Implantable Cardioverter-Defibrillator Generator Replacement. (August 2018)
- Record Type:
- Journal Article
- Title:
- Risk of Appropriate Therapy and Death Before Therapy After Implantable Cardioverter-Defibrillator Generator Replacement. (August 2018)
- Main Title:
- Risk of Appropriate Therapy and Death Before Therapy After Implantable Cardioverter-Defibrillator Generator Replacement
- Authors:
- Witt, Chance M.
Waks, Jonathan W.
Mehta, Ramila A.
Friedman, Paul A.
Kramer, Daniel B.
Buxton, Alfred E.
Mulpuru, Siva K.
Noseworthy, Peter A.
Hodge, David O.
Lushinsky, Emilie C.
Mulholland, Megan B.
Cha, Yong-Mei
Gersh, Bernard J.
Madhavan, Malini - Abstract:
- Abstract : Background: The decision to initially implant an implantable cardioverter-defibrillator (ICD) is informed by robust randomized controlled trials, but no such data exist to guide the decision to replace an ICD generator. In this study, we aimed to determine outcomes after ICD generator replacement. Methods: All patients with ischemic or nonischemic cardiomyopathy who underwent ICD generator replacement from 2001 to 2011 at Mayo Clinic, MN, or Beth Israel Deaconess Medical Center, MA, were included. Outcomes included (1) appropriate therapy after generator replacement and (2) death before appropriate therapy after generator replacement. Cox proportional hazards modeling was used to determine the associations between patient characteristics and outcomes. Results: In 1421 patients undergoing ICD generator replacement (mean±SD age 69.6±12.1 years, 81% male), appropriate therapy occurred after replacement in 435 patients (30.6%) over a mean follow-up of 2.7±2.6 years. Associated factors included lower left ventricular ejection fraction and history of appropriate therapy before generator replacement. Death before appropriate ICD therapy occurred in 336 (23.7%) patients. Older age, lower left ventricular ejection fraction, and noncardiac comorbidities, including diabetes mellitus, chronic lung disease, peripheral vascular disease, lower hemoglobin, and lower glomerular filtration rate, were associated with greater risk of death before appropriate therapy. A progressiveAbstract : Background: The decision to initially implant an implantable cardioverter-defibrillator (ICD) is informed by robust randomized controlled trials, but no such data exist to guide the decision to replace an ICD generator. In this study, we aimed to determine outcomes after ICD generator replacement. Methods: All patients with ischemic or nonischemic cardiomyopathy who underwent ICD generator replacement from 2001 to 2011 at Mayo Clinic, MN, or Beth Israel Deaconess Medical Center, MA, were included. Outcomes included (1) appropriate therapy after generator replacement and (2) death before appropriate therapy after generator replacement. Cox proportional hazards modeling was used to determine the associations between patient characteristics and outcomes. Results: In 1421 patients undergoing ICD generator replacement (mean±SD age 69.6±12.1 years, 81% male), appropriate therapy occurred after replacement in 435 patients (30.6%) over a mean follow-up of 2.7±2.6 years. Associated factors included lower left ventricular ejection fraction and history of appropriate therapy before generator replacement. Death before appropriate ICD therapy occurred in 336 (23.7%) patients. Older age, lower left ventricular ejection fraction, and noncardiac comorbidities, including diabetes mellitus, chronic lung disease, peripheral vascular disease, lower hemoglobin, and lower glomerular filtration rate, were associated with greater risk of death before appropriate therapy. A progressive increase in mortality was observed with aggregation of these noncardiac comorbidities. Conclusions: The decision to replace the ICD should take into consideration not only left ventricular ejection fraction and history of ventricular arrhythmias, but also comorbid illnesses that may impact the duration and the quality of life. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 11:Number 8(2018)
- Journal:
- Circulation
- Issue:
- Volume 11:Number 8(2018)
- Issue Display:
- Volume 11, Issue 8 (2018)
- Year:
- 2018
- Volume:
- 11
- Issue:
- 8
- Issue Sort Value:
- 2018-0011-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-08
- Subjects:
- death -- diabetes mellitus -- glomerular filtration rate -- primary -- prevention -- secondary prevention
Arrhythmia -- Periodicals
Heart -- Electric properties -- Periodicals
616.128 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01337493-000000000-00000 ↗
http://circep.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCEP.117.006155 ↗
- Languages:
- English
- ISSNs:
- 1941-3149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7414.xml