Minimally Invasive Ponto Surgery Versus the Linear Incision Technique With Soft Tissue Preservation for Bone Conduction Hearing Implants: A Multicenter Randomized Controlled Trial. Issue 7 (August 2018)
- Record Type:
- Journal Article
- Title:
- Minimally Invasive Ponto Surgery Versus the Linear Incision Technique With Soft Tissue Preservation for Bone Conduction Hearing Implants: A Multicenter Randomized Controlled Trial. Issue 7 (August 2018)
- Main Title:
- Minimally Invasive Ponto Surgery Versus the Linear Incision Technique With Soft Tissue Preservation for Bone Conduction Hearing Implants
- Authors:
- Calon, Tim G.A.
Johansson, Martin L.
de Bruijn, Arthur J.G.
van den Berge, Herbert
Wagenaar, Mariet
Eichhorn, Edwin
Janssen, Miranda M.L.
Hof, Janny R.
Brunings, Jan-Wouter
Joore, Manuela A.
Jonhede, Sofia
van Tongeren, Joost
Holmberg, Marcus
Stokroos, Robert-Jan - Abstract:
- Abstract : Objective: To compare the surgical outcomes of the Minimally Invasive Ponto Surgery (MIPS) technique with those of the linear incision technique with soft-tissue preservation for bone-anchored hearing systems (BAHS). Design: Sponsor-initiated multicenter, open, randomized, controlled clinical trial. Setting: Maastricht University Medical Centre, Ziekenhuisgroep Twente and Medisch Centrum Leeuwarden, all situated in The Netherlands. Participants: Sixty-four adult patients eligible for unilateral BAHS surgery. Interventions Single-stage BAHS surgery with 1:1 randomization to the linear incision technique with soft-tissue preservation (control) or the MIPS (test) group. Primary and Secondary Outcome Measurements: Primary objective: compare the incidence of inflammation (Holgers Index ≥ 2) during 12 weeks' follow-up after surgery. Secondary objectives: skin dehiscence, pain scores, loss of sensibility around the implant, soft-tissue overgrowth, skin sagging, implant extrusion, cosmetic results, surgical time, wound healing and Implant Stability Quotient measurements. Results: Sixty-three subjects were analyzed in the intention-to-treat population. No significant difference was found for the incidence of inflammation between groups. Loss of skin sensibility, cosmetic outcomes, skin sagging, and surgical time were significantly better in the test group. No statistically significant differences were found for dehiscence, pain, and soft-tissue overgrowth. A nonsignificantAbstract : Objective: To compare the surgical outcomes of the Minimally Invasive Ponto Surgery (MIPS) technique with those of the linear incision technique with soft-tissue preservation for bone-anchored hearing systems (BAHS). Design: Sponsor-initiated multicenter, open, randomized, controlled clinical trial. Setting: Maastricht University Medical Centre, Ziekenhuisgroep Twente and Medisch Centrum Leeuwarden, all situated in The Netherlands. Participants: Sixty-four adult patients eligible for unilateral BAHS surgery. Interventions Single-stage BAHS surgery with 1:1 randomization to the linear incision technique with soft-tissue preservation (control) or the MIPS (test) group. Primary and Secondary Outcome Measurements: Primary objective: compare the incidence of inflammation (Holgers Index ≥ 2) during 12 weeks' follow-up after surgery. Secondary objectives: skin dehiscence, pain scores, loss of sensibility around the implant, soft-tissue overgrowth, skin sagging, implant extrusion, cosmetic results, surgical time, wound healing and Implant Stability Quotient measurements. Results: Sixty-three subjects were analyzed in the intention-to-treat population. No significant difference was found for the incidence of inflammation between groups. Loss of skin sensibility, cosmetic outcomes, skin sagging, and surgical time were significantly better in the test group. No statistically significant differences were found for dehiscence, pain, and soft-tissue overgrowth. A nonsignificant difference in extrusion was found for the test group. The Implant Stability Quotient was statistically influenced by the surgical technique, abutment length, and time. Conclusion: No significant differences between the MIPS and the linear incision techniques were observed regarding skin inflammation. MIPS results in a statistically significant reduction in the loss of skin sensibility, less skin sagging, improved cosmetic results, and reduced surgical time. Although nonsignificant, the implant extrusion rate warrants further research. Abstract : Supplemental Digital Content is available in the text … (more)
- Is Part Of:
- Otology & neurotology. Volume 39:Issue 7(2018)
- Journal:
- Otology & neurotology
- Issue:
- Volume 39:Issue 7(2018)
- Issue Display:
- Volume 39, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 39
- Issue:
- 7
- Issue Sort Value:
- 2018-0039-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-08
- Subjects:
- BAHS -- Bone conduction -- Bone-anchored hearing -- Hearing loss -- Holgers index -- Minimally invasive ponto surgery -- MIPS -- Soft tissue reactions -- Surgical outcomes -- Surgical technique -- Tissue preservation
Otology -- Periodicals
Ear -- Diseases -- Periodicals
Skull base -- Surgery -- Periodicals
617.8005 - Journal URLs:
- http://www.otology-neurotology.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAO.0000000000001852 ↗
- Languages:
- English
- ISSNs:
- 1531-7129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.528000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7416.xml