Clinical Outcomes of Drug-Eluting Balloon for In-Stent Restenosis Based on the Number of Metallic Layers: The New Tokyo Registry. (August 2018)
- Record Type:
- Journal Article
- Title:
- Clinical Outcomes of Drug-Eluting Balloon for In-Stent Restenosis Based on the Number of Metallic Layers: The New Tokyo Registry. (August 2018)
- Main Title:
- Clinical Outcomes of Drug-Eluting Balloon for In-Stent Restenosis Based on the Number of Metallic Layers
- Authors:
- Yabushita, Hiroto
Kawamoto, Hiroyoshi
Fujino, Yusuke
Tahara, Satoko
Horikoshi, Takeo
Tada, Miho
Amano, Tatsuya
Onishi, Hirokazu
Nakajima, Akihiro
Warisawa, Takayuki
Watanabe, Yusuke
Yoshizaki, Toru
Mitomo, Satoru
Sato, Tomohiko
Naganuma, Toru
Ishiguro, Hisaaki
Kurita, Naoyuki
Nakamura, Shotarou
Hozawa, Koji
Nakamura, Sunao - Abstract:
- Abstract : Background: This study assesses clinical outcomes after drug-eluting balloon treatment for recurrent in-stent restenosis lesions based on the number of metallic layers. Methods and Results: We enrolled 304 consecutive patients (333 lesions) treated with percutaneous coronary intervention using drug-eluting balloon for in-stent restenosis lesions between March 2014 and June 2015. Per the number of stent layers previously implanted to the lesion, the patients were categorized into 3 groups, 1 stent layer (1L), 166 patients; 2 stent layers (2L), 87 patients; and ≥3 stent layers (≥3L), 51 patients. The end points were major adverse cardiovascular events (MACE), including cardiac death, target lesion revascularization, myocardial infarction, and definite or probable stent thrombosis. No significant differences were observed in patients' baseline characteristics among the groups. The 1-year MACE and target lesion revascularization rates were significantly higher in the ≥3L group than those in the 1L and 2L groups (MACE: 1L, 16.9%; 2L, 16.1%; and ≥3L, 43.1%, P <0.01; target lesion revascularization: 1L, 14.5%; 2L, 14.9%; and ≥3L, 41.2%, P <0.01). The multivariable Cox regression analysis revealed that the number of metallic layers (≥3L compared with 1L; hazard ratio, 3.17; [95% CI, 1.75–5.76]; P <0.01 and hemodialysis [hazard ratio, 2.21; (95% CI, 1.12–4.36); P =0.02]) were independent predictors for MACE. No significant differences were observed in the occurrence ofAbstract : Background: This study assesses clinical outcomes after drug-eluting balloon treatment for recurrent in-stent restenosis lesions based on the number of metallic layers. Methods and Results: We enrolled 304 consecutive patients (333 lesions) treated with percutaneous coronary intervention using drug-eluting balloon for in-stent restenosis lesions between March 2014 and June 2015. Per the number of stent layers previously implanted to the lesion, the patients were categorized into 3 groups, 1 stent layer (1L), 166 patients; 2 stent layers (2L), 87 patients; and ≥3 stent layers (≥3L), 51 patients. The end points were major adverse cardiovascular events (MACE), including cardiac death, target lesion revascularization, myocardial infarction, and definite or probable stent thrombosis. No significant differences were observed in patients' baseline characteristics among the groups. The 1-year MACE and target lesion revascularization rates were significantly higher in the ≥3L group than those in the 1L and 2L groups (MACE: 1L, 16.9%; 2L, 16.1%; and ≥3L, 43.1%, P <0.01; target lesion revascularization: 1L, 14.5%; 2L, 14.9%; and ≥3L, 41.2%, P <0.01). The multivariable Cox regression analysis revealed that the number of metallic layers (≥3L compared with 1L; hazard ratio, 3.17; [95% CI, 1.75–5.76]; P <0.01 and hemodialysis [hazard ratio, 2.21; (95% CI, 1.12–4.36); P =0.02]) were independent predictors for MACE. No significant differences were observed in the occurrence of cardiac death among the groups ( P =0.34). Conclusions: Seemingly, drug-eluting balloon is less effective for ≥3L in-stent restenosis lesions. Hemodialysis and in-stent restenosis with the number of metallic layers are independent predictors for MACE. … (more)
- Is Part Of:
- Circulation. Volume 11:Number 8(2018)
- Journal:
- Circulation
- Issue:
- Volume 11:Number 8(2018)
- Issue Display:
- Volume 11, Issue 8 (2018)
- Year:
- 2018
- Volume:
- 11
- Issue:
- 8
- Issue Sort Value:
- 2018-0011-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-08
- Subjects:
- drug-eluting stents -- incidence -- myocardial infarction -- percutaneous coronary intervention -- thrombosis
Cardiovascular system -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Treatment -- Periodicals
616.105 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=01337495-000000000-00000 ↗
http://circinterventions.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCINTERVENTIONS.117.005935 ↗
- Languages:
- English
- ISSNs:
- 1941-7640
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262560
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7406.xml