A Novel Method for the Approximation of Humeral Head Retrotorsion Based on Three-Dimensional Registration of the Bicipital Groove. (1st August 2018)
- Record Type:
- Journal Article
- Title:
- A Novel Method for the Approximation of Humeral Head Retrotorsion Based on Three-Dimensional Registration of the Bicipital Groove. (1st August 2018)
- Main Title:
- A Novel Method for the Approximation of Humeral Head Retrotorsion Based on Three-Dimensional Registration of the Bicipital Groove
- Authors:
- Vlachopoulos, Lazaros
Carrillo, Fabio
Dünner, Celestine
Gerber, Christian
Székely, Gábor
Fürnstahl, Philipp - Abstract:
- Abstract : Background: The accurate restoration of premorbid anatomy is key for the success of reconstructive surgeries of the proximal part of the humerus. The bicipital groove has been proposed as a landmark for the prediction of humeral head retrotorsion. We hypothesized that a novel method based on bilateral registration of the bicipital groove yields an accurate approximation of the premorbid anatomy of the proximal part of the humerus. Methods: Three-dimensional (3D) triangular surface models were created from computed tomographic data of 100 paired humeri (50 cadavers). Segments of the distal part of the humerus and the humeral shaft of prespecified lengths were defined. A surface registration algorithm was applied to superimpose the models onto the mirrored contralateral humeral model based on the defined segments. We evaluated the 3D proximal humeral contralateral registration (p-HCR) errors, defined as the difference in 3D rotation of the humeral head between the models when superimposed. For comparison, we quantified the landmark-based retrotorsion (LBR) error, defined as the intra-individual difference in retrotorsion, measured with a landmark-based 3D method. Results: The mean 3D p-HCR error using the most proximal humeral shaft (bicipital groove) segment for the registration was 2.8° (standard deviation [SD], 1.5°; range, 0.6° to 7.4°). The mean LBR error of the reference method was 6.4° (SD, 5.9°; range, 0.5° to 24.0°). Conclusions: Bilateral 3D registrationAbstract : Background: The accurate restoration of premorbid anatomy is key for the success of reconstructive surgeries of the proximal part of the humerus. The bicipital groove has been proposed as a landmark for the prediction of humeral head retrotorsion. We hypothesized that a novel method based on bilateral registration of the bicipital groove yields an accurate approximation of the premorbid anatomy of the proximal part of the humerus. Methods: Three-dimensional (3D) triangular surface models were created from computed tomographic data of 100 paired humeri (50 cadavers). Segments of the distal part of the humerus and the humeral shaft of prespecified lengths were defined. A surface registration algorithm was applied to superimpose the models onto the mirrored contralateral humeral model based on the defined segments. We evaluated the 3D proximal humeral contralateral registration (p-HCR) errors, defined as the difference in 3D rotation of the humeral head between the models when superimposed. For comparison, we quantified the landmark-based retrotorsion (LBR) error, defined as the intra-individual difference in retrotorsion, measured with a landmark-based 3D method. Results: The mean 3D p-HCR error using the most proximal humeral shaft (bicipital groove) segment for the registration was 2.8° (standard deviation [SD], 1.5°; range, 0.6° to 7.4°). The mean LBR error of the reference method was 6.4° (SD, 5.9°; range, 0.5° to 24.0°). Conclusions: Bilateral 3D registration of the bicipital groove is a reliable method for approximating the premorbid anatomy of the proximal part of the humerus. Clinical Relevance: The accurate approximation of the premorbid anatomy is a key for the successful restoration of the premorbid anatomy of the proximal part of the humerus. … (more)
- Is Part Of:
- Journal of bone and joint surgery. Volume 100:Number 15(2018)
- Journal:
- Journal of bone and joint surgery
- Issue:
- Volume 100:Number 15(2018)
- Issue Display:
- Volume 100, Issue 15 (2018)
- Year:
- 2018
- Volume:
- 100
- Issue:
- 15
- Issue Sort Value:
- 2018-0100-0015-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-08-01
- Subjects:
- Bones -- Surgery -- Periodicals
Joints -- Surgery -- Periodicals
Orthopedics -- Periodicals
Orthopedics
General Surgery
Bone Diseases
Joint Diseases
Bones -- Surgery
Joints -- Surgery
Orthopedics
Bot (anatomie)
Gewrichten
Chirurgie (geneeskunde)
Periodicals
Electronic journals
Periodicals
617.47005 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/00219355 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219355 ↗
http://www.ejbjs.org/contents-by-date.0.dtl ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.2106/JBJS.17.01561 ↗
- Languages:
- English
- ISSNs:
- 0021-9355
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.250000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7385.xml